NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.; 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyfe: ASBESTOS
3 Werner Way. Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code; 101953
Dale Analyzed; 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B385
Site; 3 World Financial Center - Floors 3-26
SAMPLE
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB»
CLIENTS SAMPLE »
7001 7th Floor/ South East Corner/ South/ BROWN NO 0% CELL 30%
9/28/01 Sample of Debris NFIB 70%
11017
7-001
7002 7th Floor/ South East Corner/ South/ GRAY NO 0% CELL 5%
9/28/01 Sample of Debris FBGL 20%
11018 NFIB 75%
7-002
7003 7th Floor/ South East Corner/ North/ GRAY NO 0% FBGL 30%
9/28/01 Sample of Debris NFIB 70%
11019
7-003
7004 7th Floor/ South East Corner/ Central - GRAY/ NO 0% CELL 10%
9/28/01 East/ Sample of Debris WHITE FBGL 10%
11020 NFIB 80%
7-004
’INSUFFICIENT MATERIAL SUBMITTED ’’TEM RECOMMENDED *"NOT ANALYZED POSITIVE STOP
Samole Analysis bv* ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Samrrle Preparation and Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples vyere prepared and analyzed in accordance with Ihe EPA TREM = Tremolite Asbestos CELL = Cellulose
TVIelhod for Ihe Determination of Asbestos in Bulk Building Materials' ANTH = Anthophylite Asbestos NFIB = Mon-Fibrous
USEPA/BOOT R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR= Horse Hair
/Qzi ex fA^ OTHR = Other
Olympus PLM, Model BH-Z/VM Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical resuhs reflect Ihe make up of the materials only in Ihe areas sampled. This "Summary of Analytical Results* shall not be reproduced except in full, without Ihe write
approval of JLC Laboratory, and it must not be used by client Io claim product endorsement by NVLAP or any agency of the U.S. Government. This method is riot appOcable to
samples containing large amounts of Fine fibers below Ihe resolution of Ihe light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was . .
determined with a visual volume estimate; a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties simitar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently Ihe only method that can be used to determine if this material can b- .
considered or treated as non-asbestos containing.
Page 1 of 3
CITY_21MC100_002821043
NYC-WTC_000268953
OCR can misread numbers and units. Confirm readings against the page image before using them.