KAMCONSUUMiTS 35-40 36th Street bng Island City NewYork,11106 Tel: (718)729-1997 Fax: 718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# • 16 17 18 19 20

Lab Sample ID- 01 0904A-131 010904A-132 010904A-133 010904A-I34 010904A-135 Sample Location 4th Floor 4th Floor 4th Floor 3rd Floor 3rd Floor Interior Walls Interior Walls Interior Walls Interior Walls Interior Walls Around W'indows Around Windows Around Windows Around Windows Around Windows Homogeneity Yes Yes Yes Yes Yes Sample Description Sheetrock Sheetrock Sheetrock Sheetrock Sheetrock

Color Wh Uh Wh Uh Wh Texture Mixed Mixed Mixed Mixed Mixed Sample Treatment None None None None None

Asbestos Present (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr Mat. (Type & Percent) 5%CELL 5%CELL 5%CELL 5%CELL 5%CELL 5%FBGL 5%FBGL 5%FBGL 7%FBGL 15%FBGL Non Fibr Mat (Percenti­ 90% 90% 90% 88% 80% Date Received 9/4/01 Date of Analysis 9/5/01 Date of Report 9/5/01

Analyst: Lab Mana Mark Ulanecki David Chen * Analysis of samples is performed by Polarized Lisht Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-ffiable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 MST-Zy/rLAP » 102047 AlHAff: 100269

4

CITY_21MC1OO_OO2784984

NYC-WTC_000268397

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268397Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000268217

Summary of environmental surveys and dust monitoring post-9/11 for DCAS facilities.

Similar indexed content

Compare copies and versions →