Bulk sample analysis, 14-22 [name] Manhattan

Machine-extracted title · confidence 43%

Bulk sample analysis for NYC-DCAS at 14-22 [name], listing Lab Sample IDs and floors.

NYC-WTC_000268226–000268231
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUANTS 35-40 36th Street Long Island City NewYork, 11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS; 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# : 21 22 23 24 Lab Sample ID# : 010904A-136 01O904A-137 0109O4A-138 010904A-139 Sample Location; 3rd Floor 2nd Floor 2nd Floor 2nd Floor Interior Walls Interior Walls 'Interior Walls . Interior Walls Around Windows Around Windows A ound Windows Around Window;; Homogeneity: Yes Yes Yes Yes Sample Description; Sheetrock Sheetrock Sheetrock Sheetrock

Color: Wh Wh Wh Wh Texture: Mixed Mixed Mixed Mixed Sample Treatment; None None None None

Asbestos Prese:nt; (Type & Percent) ND ND ND ND Total Percent Asbestos: 0% 0% 014 0% Other Fibr. Mat. (Type & Percent); 5%CELL 5%CELL SToCELL 5%CELL 15%FBGL 15%FBGL 15%FBGL 15%FBGL Non Fibr. Mat. (Percent): 80% 80% 80% 80% Date Received; 9/4/01 Date of Analysis; 9/5/01 Date of Report: 9/5/01 Analyst: ■ lO f 6l Adtck-i Lab Mana^r: Mark Ulanecki David Chen * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; Stereobinocular microscope (MEIJI EiMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing ♦ Ssimples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 NIST-NVLAP if 102047 AIHA#: 100269

5

CITY_21MC100_006262458

NYC-WTC_000268231

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268231Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000268217

Summary of environmental surveys and dust monitoring post-9/11 for DCAS facilities.

Similar indexed content

Compare copies and versions →