KAM CONSULTANTS 35-40 36th Street Long Island City New York, 11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: CITYHALL NY, NY PROJECT#: Client Sample ID# 1 2 3 4 5 Lab Sample ID# : 010915 A-726 010915A-727 010915A-728 010915A-729 01O9I5A-730 N/E comer rm betw 3rd floor office 3rd floor corridor 3rd floor corridor 3rd floor office 2nd&3rd floor North side North side West side South West side

Homogeneity: Yes Yes Yes Yes Yes Sample Description wipe/desk wipe/desk wif>e/table wipe/metal chest wipe/table

Color: Blk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None: None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat (Type & Percent): 5%CELL 10%CELL 12</oCELL 15%CELL 10%CELL

Non Fibr. Mat. (Percent): 95% 90% 88Yo 85.00% 90% Date Received: 9/15/01 Date of Analysis: 9/15/01 Date of Report: 9/16/01 D- clocn Analyst: M'. uln rtpcic 1' Lab Manager: M. Ulanecki David Chen * Analysis of samples is performed by Polarized Light Microst opy (PLM) - Point Counting Method (EPA 600/M4-82-020) ♦ Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930). Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. ♦ The certificate of report shall not be reproduced without the wTitten approval of the laboratory. * The reptort must not be used by the client to claim endorsement by NVLAP or any agency of the US Government NYS-DOffELAP »11273 NIST-NVLAP# 102047 A/HA 100269

1

CITY_21MC1OO_OO6262399

NYC-WTC_000268197

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268197Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →