KAMCONSUUANTS 35-4(136th Street Long Island City New York. 11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: CITYHALL NY, NY PROJECT#: Client Sample ID# 1 2 3 4 5 Lab Sample ID# : 010915A-726 010915A-727 010915A-728 010915A-729 010915A-730 N/E comer rm berw 3rd floor office 3rd floor corridor 3rd floor corridor 3rd floor office 2nd&3rd floor North side North side West side South West side

Homogeneiry: Yes Yes Y.;s Yes Yes Sample Description wipe/desk wipe/desk wipe/table wipe/metal chest wipe/table

Color: Blk BIk BA BIk BIk Texture: Mixed Mixed Mixed Mixed Mixed Sample 7 reatmenl; None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent); 5%CELL 10%CELL 12%CELL I5%CELL i0%CELL

Non Fibr. Mat. (Percent): 95% 90% 88% 85.00% 90% Date Received; 9/15/01 Date of/tnalysis: 9/15/01 Date of Report: 9/16/01 Analyst: M- uin apcJc. i Lab Manager; M. Ulanecki David Chen * Analysis of samples is performed bv Polarized Light Microscoov (PLM) - Point Counting Method lEPA 600/M4-82-020) * Analvlical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) ♦ PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Ouantitative transmission electron microsicopv is currently the only method that can be used to determine if this material can be considered or treated as non-asfiestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. • The reixjrt must not be used bv the client to claim endorsement bv NVL AP or anv agency of the US Government. NYS-OOH ELAP a 11273 NIST-NVLAPH102047 AIHA 0; 100269

1

CITY_21MC100_002830853

NYC-WTC_000386383

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386383Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →