. KAM CONSULTANTS
35-40 36tb Street
Long IslandCity
NewYork,11106
Tel:{718)729-W
Fax:(718)729-1876
BULK SAMPLE A^ALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: 60 Centre Street, Manhattan, NY
PROJECT#:
Client Sample ID# : 31 32 33 34 35
Lab Sample ID# . 010919B-1152 010919B-1153 010919B-1154 010919B-1155 010919B-1156
Sample Location Hallway - By Room 335 Room 335 Room 335 Room 300
Stair 4M1 Top of Desk Robing Room Robing Room Top of Desk
Floor Window Sill Wall Vent Exhaust
Homogeneity Yes Yes Yes Yes Yes
Sample Description Dust Dust Dust Dust Dust
Wipe Wipe Vk ipe Wipe Wipe
Color Blk Blk Blk Blk Blk
Texture Mixed Mixed Mixed Mixed Mixed
Sample Treatment. None None None None None
Asbestos Present
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr. Mat.
(Type & Percent) 2%SYNTH 2%SYNTH 5%SYNTH 2%SYNTH 2%SYNTH
<1%FBGL <1%FBGL
Non Fibr Mat.
(Percent)- 98% 98% 95% 97% 97%
Date Received. 9/19/01
Date of Analysis: 9/19/01
Date of Report: 9/19/01
Analyst: Lab Manager: [
Roody Louis David Chen
* Analysis of samples is performed by Polarxed Light Micro- copv (PLM) - Point Counting Method
(EPA 600/M4-82-020)
* Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930). Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron micros :opv is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
♦ The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the written approval of the laboratory.
♦ The report must not be used by the client to claim endorsem ;nt by NVLAP or any agency of the US Government.
i\YS-DOH ELAP » J1273 MST-Nl^LAP ft 192047 A/HAU; 100269
CITY_21MC100_0 02777730