NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Bulk sample analysis report, 31 [name] units

Machine-extracted title · confidence 43%

Bulk asbestos analysis of room A/C, roof and units at 31 [name], NYC-DCAS project; homogeneity noted.

NYC-WTC_000268171–000268172
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36th Street N Long l5l a nd City NewYork,11106 Tel: (718 723-1937 k Fax: (718 729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC DCAS BUILDING ADDRESS: 31 Chamber Street, Manhattan, Ne« York PROJECT#: Client Sample ID# : 6 7 !i 9 10 Lab Sample ID#: 010926A-1841 010926A-1842 010926A-1843 010926A-1844 010926A-1845 Sample Location; Roof - Air Roof - Elevator Roof - Bulkhead Penthouse - 7th Floor - Shaft Room Facing South Room 715 (Lunch Room)

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Duct Window Stair Window Window Sill Wipe Wipe Wipe Wipe Wipe

Color: Blk Blk 31k Blk Blk Texture; Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent); 1%SYNTH 5%SYNTH 2%SYNTH 5%SYNTH 2%SYNTH 2%CELL 3%CELL <1%FBGL 3%CELL Non Fibr. Mat. (Percent); 97% 92% 98% 94% 95% Date Received; 9/26/01 Date of Analysis: 9/26/01 Date of Report: 9/26/01

Analyst: Lab Manag Roodv/Louis David Chen * Analysis of samples is performed byrolarized Light Microsccpv (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-ffiable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non- asbestos-containing * Samples will be stored for ninety (90) days and then returned lo the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement bvNVLAP or any agency of the US Government. NYS-DOH ELAP #11273 NIST-N^LAP # 102047 AIHA #: 100269

2

CITY_21MC100_006262357

NYC-WTC_000268172

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268172Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →