Bulk sample analysis, 010918B-980 to -983

Machine-extracted title · confidence 46%

Bulk sample IDs for 010918B series from NYC-DCAS project, South/East/West locations.

NYC-WTC_000268161
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUMfTS 3S-403fithStmt Long Island City NowYork,11106 Tel:ai8)729-19J7 Fax: (718)729-1876 'ilw

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: III Centre Street PROJECT#: Client Sample ID# : 21 23 24 Lab Sample ID# : 010918B-980 010918B-981 01O918B-982 010918B-983 Sample Location: South East South West South West South West Entrance Entrance Judge Room Judge Room Lobby Lobby Lobby Lobby Floor Level Homogeneity: Yes Yes Yes Yes Sample Description: Floor Floor Vv'indow Sill Window Sill Wipe Wipe Wipe Wipe

Color: Gr Gr Gr Gr Texture: Mixed Mixed Mixed Mixed Sample Treatment: None None bone None

Asbestos Present: (Type & Percent) ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 5%CELL 8%CELL 10%CELL 10%CELL 15%SYNTH 3%SYNTH Non Fibr. Mat. (Percent): 80% 92% 87% 90% Date Received: 9/18/01 Date of Analysis 9/18/01 Date of Report: 9/18/01

Analys Lal) Manag^: I 1 Roody Louis ) ’ David Chen ' * Analysis of samples is performed bv Polarized Light Microscot)v (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-a sbestos-containing * Samples will be stored for ninety (90) days and then returned tc the client upon request * The results relate only to the items calibrated or tested. ■*.<r * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP »11273 y/ST-WLAP # 102017 AIHA #: 100269

5

CITY_21MC100_0 06262324

NYC-WTC_000268161

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268161Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →