Bulk sample analysis report, 280 Broadway

Machine-extracted title · confidence 42%

Lab IDs and locations for bulk samples at 280 Broadway, Manhattan.

NYC-WTC_000266425–000266434
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ivuMuunouunniQ 35-40 3tth Street ■ u. Long Island City

" (1 NewYork,11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE AFiALYSlS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 280 Broadway, Manhattan, NY PROJECT#: Client Sample ID# I 2 3 4 3

Lab Sample 0109226-1389 0109226-1390 0109226-1391 0109226-1392 0109226-1393

Sample Location Sth Floor Sth Floor Sth Floor Elevator Machine Machine Elevator Pent House Pent House Pent House Room West Exit Room Chamber W indow South Window West to Roof Chamber Street Entrance Street Entrance Homogeneity Yes Yes Yes Yes Yes

Sample Description W indow Sill Window Sill Tool Boxes Door Step El Motor Surface W ipe W ipe Wipe Wipe Wipe

Color Elk BIk 81k Blk Gr 6rn

Texture Mixed Mixed Mixed Mi\eJ Mixed

Sample Treatment None None None None None

Asbestos Present (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr Mat (Type & Percent) 10%CELL d’oCELL 3%CELL 5%CELL 15%CELL

Non Fibr. Mat. (Percent) 90»-o 97% 95% 95% 85% Date Received’ 9/22/01 Date of Analysis 9/23/01 Date of Report

Analyst: 9/24/01 (Wj Lab Manager: M/ric Ulanecki David Chen * Analysis of samples is perfc, n^ed by Polarized Light Micro: cocv (PLM) - Point Counting Method (EPA 600/M4-82-020) * Anaivtical equipments. Stereobinocular microscope (MEIJI EMf-Serial # 25930). Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floc r coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as lon-asbestos-containing * Samples will be stored for ninety (90) days and then returne 1 to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the vritten approval of the laboratory * The report must not be used by the client to claim endorsemt nt by NVLAP or any agency of the US Government NYS-DOH ELAP# 11273 MST-NVLAP » '02047 AJHA #: 100269

1

CITY_21MC100_0 02777783

NYC-WTC_000266425

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266425Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →