Bulk sample analysis report, City Hall, NYC-DCAS

Machine-extracted title · confidence 43%

Lab IDs and room locations for bulk samples at City Hall, NYC-DCAS project.

NYC-WTC_000266408–000266410
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAWCONSbUANTS 35-« 36th Street Long Island City NewYork.11106 Tel: {718)729-1997 Fax: 718)729-1876

BULK SAMPLE A^ ALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: CITYHALL NY, NY PROJECT#: Client Sample ID# 6 7 9 10 Lab Sample ID# ; 0I0915A-731 0I0915A-732 ('10915A-733 010915A-734 010915A-735 3rd floor corridor 3rd floor , rd floor Basement Basement South East side South Conf Rm ; outh West Rm West corridor Suite # lA

Homogeneity: Yes Yes es 'I'es Yes Sample Description wpe/wooden floor wipe/tloor vipc/desk \\ipe/ceramie tloor wipe/desk

Color; Blk Blk lilk Blk Blk Texture: Mixed Mixed ilixed Mixed Mixed Stimple Treatment: None None None None None

Asbestos Present; (Type & Percent) NT) ND ND ND ND Total Percent .Asbestos: 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 10%CELL 30%CELL 10%CELL 15%CEI,L 10%CELL 10%FBGL 10%FBGL Non Fibr. Mat. (Percent); 90% 60% ( 90% 85.00% 80% Date Received: 9/15/01 Date of Analysis: 9/15/01 Date of Report: 9/16/01

Analyst; M Ulaneeki Lab Manager. M. Ulanecki David Chen * Analysis of samples is performed bv Polarized Light Micrcscopv (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Ouantitative transmission electron micro: copy is currently the only method that can be used to determine if this material can be considered or treated as non-asbcstos-containing * Samples will be stored for ninety (90) days and then retumi d to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used bv the client to claim endorsement by NVLAP or any agency of the US Gotemment. 14YS-DOH ELAP tf 11273 MST-N^LAP it 102147 A IHA U: 100269

2

CITY_21MC100_002777768

NYC-WTC_000266409

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266409Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →