NYC 9/11 Public Portal Document
ivuiivuiwuuniiiu
35-40 StthStlNt
Long Island City
NewYort,11106
Tel:(n8|729-W
Fax; (718)729-1876
BULK SAMPLE APfALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: III Centre Street
PROJECT#:
Client Sample ID# . 16 17 18 19 20
Lab Sample ID# . 010918B-975 0I0918B-976 010918B-977 010918B-978 010918B-979
Sample Location North Window Locker Room Staicase "B" North Entrance South Entrance
3rd Floor North 3rd Floor Lobby Lobby
3rd Floor
Homogeneity: Yes Yes Yes Yes Yes
Sample Description Window Sill Window Sill Floor Floor Window Sill
ipe Wipe Wipe Wipe Wipe
Color Gr Gr Gr Gr Gr
Texture Mixed Mixed Mixed Mixed Mixed
Sample Treatment. None None None None None
Asbestos Present:
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr Mat.
(Type & Percent): 2%SYNTH 3%CELL 5%CELL 4%CELL 5%CELL
2%SYNTH 10%SYNTH 8%SYNTH
Non Fibr. Mat.
(Percent)' 92% 95% 85% 88% 95%
Date Received' 9/18/01
Date of Analysis: 9/18/01
Date of Report 9/18/01
Analystj^ K
Roody Loui^
L ' ^50
Lab Manager: | /, (
_ J,
EJavid Cfien
* Analysis of samples is performed bv Polai/zed Light Micros ropy (PLM) - Point Counting Method
(EPA 600/M4-82-020) V
* Analytical equipments: StereobinocuWr microscope (MEIJI EMT-Serial ft 25930). Polarized Light Microscope
(MEIJI ML-POL-Serial ft 88034)
* PLM is not consistently reliable in detecting asbestos in floo- coverings and similar non-friable organically
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the 'vritten approval of the laboratory.
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government.
NYS-DOH ELAP »11273 NIST-NyiAP ft IC2047 AIHA ft: 100269
4
CITY_21MC100_0 02777757
NYC-WTC_000266399
OCR can misread numbers and units. Confirm readings against the page image before using them.