KAUC0NSUUANI8 3S-403KhSlreet ZJUkzt Long Island City

I , 'I NswYork.fflOS Tel:(I18)I29-W Fax: {718)729-1876

BULK SAMPLE AI^ALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: HI Centre Street PROJECT#: Client Sample ID# : 21 23 24 Lab Sample ID# 010918B-980 010918B-981 010918B-982 010918B-983 Sample Location South East South West South West South West Entrance Entrance Judge Room Judge Room Lobby Lobby Lobby Lobby Floor Level Homogeneity. Yes Yes Yes Yes Sample Description Floor Floor Window Sill Window Sill Wipe Wipe Wipe Wipe

Color Gr Gr Gr Gr Texture Mixed Mixed Mixed Mixed Sample Treatment: None None None None

Asbestos Present; (Type & Percent) ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent)’ 5%CELL 8%CELL 10%CELL lO’/oCELL 15%SYNTH 3%SYNTH Non Fibr. Mat. (Percent)’ 80% 92% 87% 90% Date Received: 9/18/01 Date of Analysis 9/18/01 Date of Report. 9/18/01

Analyst* Roody Louis J Lab Manai •4 I4 David Chen * Analysis of samples is performed bv Polarized Liaht Microscopv (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocularmicroscope (MEIJI .TMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in flooi coverings and similar non-friable organically bound materials. Quantitative transmission electron microsc mv is currently the only method that can be used to determine if this material can be considered or treated as ron-asbestos-containing * Samples will be stored for ninety (90) days and then returnee to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the v ritten approval of the laboratory. * The report must not be used by the client to claim endorsement bv NVLAP or any agency of the US Government NYS-DOH ELAP »11273 NIST-yyLAP it 102047 AIHA #: 100269

5

CITY_21MC100_0 02777758

NYC-WTC_000266400

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266400Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →