Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 10/20/08 Floor Zip Borough Block Lot Squad # Badge # Various 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU0086MN08 yes Contractor’s Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 1:20 pm to 2:30 pm

I arrived at the premise at 1:20 pm. LVI schedule informed that activities include cut raceways North side, direct installing fall protection cables on 9*' floor, demo, box debris on 8"’, 7'^ and 6'" floors.

I proceeded to the decon, don the appropriate level of personal protective equipment to enter the regulated area on 9"’ floor. Two workers were cleaning decon. Negative air pressure on the floor was 0.044. 9*” Floor - 17 workers were present on site. Workers on 4 scaffolds on North side of the work area were cutting raceways with the power tools attached to the HEPA vacuum, spraying with amended water, carpenters setting up the platforms inside the shaft area; others were demolishing the air duct, cutting into the pieces, cleaning the floor from debris, cutting metal into pieces, using power tool attached to the HEPA vacuum, preparing and wrapping boxes for debris. 10 Gaylord boxes were ready for load out. Inspection was done on micro trap machines and micro trap tents. Filters on micro traps were dirty; handlers supervisor was advised to replace them. Air monitoring pumps were powered on. I used B stairs to proceed to the Sth floor. 8"' Floor - 13 workers were found on the floor in the process of removing air duct on the north/west side of the area, pipes and cutting into pieces, using tools with HEPA vacuum attached, carpenters working on putting the platforms across the shaft area, preparing and wrapping boxes, lifting up the electrical cables. I observed 3 holes on the wall by the critical barriers. Supervisor was advised and he directed the workers to re-seal the holes. 4 Gaylord boxes were ready for load out. 20 micro trap machines were powered on and 5 were on stand by. Inspection was done on micro trap tents. I used B stairs to proceed to the 7"’ Floor. 7*’’ Floor - 17 workers were working on the floor, removing the pipes from the ceiling, cutting them into the pieces with power tools attached to the HEPA vacuum, spraying with amended water around the area, electricians working with electrical wires, replacing micro trap machine with the machine was on stand by, refreshing the filters, preparing and wrapping boxes for debris. 13 Gaylord boxes were ready to be taken out. Inspection was done on micro trap tents. I used B stairwell to proceed to the 6*' floor. 6'" Floor - 19 workers were present on the floor. A large amount of poly wrapped beams exists on the floor in various locations. Workers were in the process of demolishing the wall in shaft area, cutting metal fixtures from the ceiling, wrapping beams with poly, cutting metal into pieces, spraying with amended water, carpenters were working inside the shaft area; others were preparing boxes for debris. 5 Gaylord boxes were ready for load out. 20 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents. I used B stairwell to go back to the S'" floor, proceeded to the decon, showered out and signed the log book

I used the north side hoist to get to the ground floor. Inspection was done on ATC trailer. I observed 2 holes on the floor of the trailer, which was re-taped by the workers immediately.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor’s^j^al

Borough 1 “Manhattan 2=Bronx 3=Brooklyn 4 Queens 5=Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130948

NYC-WTC_000266028

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266028Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →