NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 10/04/08
Floor Zip Borough Block Lot Squad # Badge #
Various 1 liliTiT 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU0086MN08 No
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnei Javal, Sr. Proj. Mgr/TRC Environmental 9:30 am to 10:45 am
I arrived at the premise at 9:30 am. LVI schedule informed that activities include direct installing
fall protection cables on 11*’floor, scrape fireproofing, boxing debris, Eagle putting platform across shafts
on io'” Floor, demo shafts, boxing debris on 9*' floor, demo, box debris on 8*’ floor.
I proceeded to the decon, followed all precautions necessary and entered containment
on 11*’floor. Negative air pressure on the floor was 0.066. One worker was cleaning the decon.
11"' Floor - Two workers were on site placing debris to the boxes and spraying with amended water.
12 Gaylord boxes were ready for load out. 20 micro trap machines were powered on and 5 on
stand by. Inspection was done on micro trap tents. Air monitoring pumps were on.
I used B stairs to proceed to the lo"' Floor.
io'” Floor - 49 workers were present on site. Workers on 6 scaffolds on south/east side of work area were
scraping, cleaning the ceiling from fireproofing, spraying with amended water, cleaning the floor from
debris and dust, placing into the boxes. On south side of the floor at the area 3 workers were on
six scaffolds and ladder fine cleaning the ceiling, the top of the tents, vacuuming the water from
ceiling cleaning, preparing the work area 3 for TRC inspection. 5 Gaylord boxes were ready for load out.
20 micro trap machines were powered on and 5 were on stand by. Inspection was done on micro trap tents.
Using B stairwell I proceeded to the 9"’ Floor.
9” Floor - 28 workers on the floor were found in the process of removing the metal door of the elevator
and sheetrock in the shaft area, spraying with amended water, one worker was working with his
arms exposed, he was told to cover his arm with suit sleeve and duct tape. Two workers were cutting
metal, placing to the boxes and spraying. I observed the water leak across the west side critical
barriers. Handlers Supervisor directed the workers immediately to correct the leakage, collect the water
and dispose properly. Other workers were preparing boxes, removing debris from the floor, spraying
around the work area. 14 Gaylord boxes were ready for load out. Inspection was done on micro
trap machines and tents.
I used B stairs to. proceed to the 8'” Floor.
8"' Floor - 18 workers were present on the floor. A large amount of poly wrapped beams exists on the
floor. Workers were removing metal pipes and fixtures from the ceiling, cutting electrical cables, air ducts,
placing debris into the boxes and spraying with amended water, preparing boxes, removing debris from
the floor. I observed that electrical cables were hanging down and filters on micro trap machines were
dirty. Supervisor on the floor was advised to direct the workers to replace the filters and elevate
the cables.
12 Gaylord boxes were ready to be taken out. Inspection was done on micro trap machines and tents.
Using B staircase I went back to the 11"’ floor.
After following the decontamination procedure
I signed the log book and used north hoist to get to the ground floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhattan 2=Bronx 3=Brook.lyn 4=Queens 5=Richinond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Projecl not started (no NOV)
5=Public Owned Property