Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 10/04/08 Floor Zip Borough Block Lot Squad # Badge # Various 1 liliTiT 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU0086MN08 No Contractor’s Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnei Javal, Sr. Proj. Mgr/TRC Environmental 9:30 am to 10:45 am

I arrived at the premise at 9:30 am. LVI schedule informed that activities include direct installing fall protection cables on 11*’floor, scrape fireproofing, boxing debris, Eagle putting platform across shafts on io'” Floor, demo shafts, boxing debris on 9*' floor, demo, box debris on 8*’ floor.

I proceeded to the decon, followed all precautions necessary and entered containment on 11*’floor. Negative air pressure on the floor was 0.066. One worker was cleaning the decon. 11"' Floor - Two workers were on site placing debris to the boxes and spraying with amended water. 12 Gaylord boxes were ready for load out. 20 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents. Air monitoring pumps were on. I used B stairs to proceed to the lo"' Floor. io'” Floor - 49 workers were present on site. Workers on 6 scaffolds on south/east side of work area were scraping, cleaning the ceiling from fireproofing, spraying with amended water, cleaning the floor from debris and dust, placing into the boxes. On south side of the floor at the area 3 workers were on six scaffolds and ladder fine cleaning the ceiling, the top of the tents, vacuuming the water from ceiling cleaning, preparing the work area 3 for TRC inspection. 5 Gaylord boxes were ready for load out. 20 micro trap machines were powered on and 5 were on stand by. Inspection was done on micro trap tents. Using B stairwell I proceeded to the 9"’ Floor. 9” Floor - 28 workers on the floor were found in the process of removing the metal door of the elevator and sheetrock in the shaft area, spraying with amended water, one worker was working with his arms exposed, he was told to cover his arm with suit sleeve and duct tape. Two workers were cutting metal, placing to the boxes and spraying. I observed the water leak across the west side critical barriers. Handlers Supervisor directed the workers immediately to correct the leakage, collect the water and dispose properly. Other workers were preparing boxes, removing debris from the floor, spraying around the work area. 14 Gaylord boxes were ready for load out. Inspection was done on micro trap machines and tents. I used B stairs to. proceed to the 8'” Floor. 8"' Floor - 18 workers were present on the floor. A large amount of poly wrapped beams exists on the floor. Workers were removing metal pipes and fixtures from the ceiling, cutting electrical cables, air ducts, placing debris into the boxes and spraying with amended water, preparing boxes, removing debris from the floor. I observed that electrical cables were hanging down and filters on micro trap machines were dirty. Supervisor on the floor was advised to direct the workers to replace the filters and elevate the cables. 12 Gaylord boxes were ready to be taken out. Inspection was done on micro trap machines and tents. Using B staircase I went back to the 11"’ floor.

After following the decontamination procedure I signed the log book and used north hoist to get to the ground floor. Inspection was done on ATC trailer.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor’s Initial

Borough l=Manhattan 2=Bronx 3=Brook.lyn 4=Queens 5=Richinond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Projecl not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130862

NYC-WTC_000265977

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000265977Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →