I Pace Analytical Services, Inc
1700 Elm Street - Suite 200
Minneapolis, MN 55414
I ^ceAnalvticar_________ Method 8290 Analysis Results
Tel 612-607-1700
Fax 612-607-6444
Client - ATC
I' Client's Sample ID
Lab Sample ID
ATC-0214-M894-DX3
103331831
Filename U20306A_07
I Injected By
Total Amount Extracted
CVS
1 m2 Matrix WIPE
% Moisture NA Dilution NA
I Dry Weight Extracted
ICAL Date
CCal Filename(s)
NA
03/05/2002
U20305B_16 & U20306A_17
Collected
Received
Extracted
02/14/2002
02/18/2002
02/28/2002
Method Blank ID BLANK-1489 Analyzed 03/06/2002 20:02
(
Native Cone EMPC LRL Internal ng's Percent
isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 67
I Total TCDF 0.0066 0 00200 J 2,3,7,8-TCDD-13C
1,2,3,7.8-PeCDF-13C
2 00
2.00
65
78
2,3,7,8-TCDD ND 0 00200 2,3.4,7,8-PeCDF-13C 2.00 65
Total TCDD 0.0049 0.00200 J 1,2,3,7,8-PeCDD-13C 2.00 72
I 1,2,3,7,8-PeCDF ND 0.01000
1.2,3.4,7,8-HxCDF-13C
1,2,3,6,7,8-HxCDF-13C
2.00
2.00
86
75
2,3.4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 77
Total PeCDF ND 0.01000 1,2,3,7.8,9-HxCDF-13C 2.00 74
I 1,2,3,7,8-PeCDD ND 0.01000
1,2,3,4,7,8-HxCDD-13C
1,2,3,6,7,8-HxCDD-13C
2.00
2.00
85
69
Total PeCDD ND 0.01000 1.2,3,4,6,7,8-HpCDF-13C 2.00 79
1,2,3.4.7,8,9-HpCDF-13C 2.00 76
I 1.2,3,4,7,8-HxCDF
1,2,3,6,7.8-HxCDF
ND
ND
0.01000
0 01000
1,2,3,4,6,7,8-HpCDD-13C
OCDD-13C
2.00
4.00
77
62
2,3,4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
I Total HxCDF ND 0.01000 1,2,3,7,8.9-HxCDD-13C 2 00 NA
1,2.3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 74
1,2,3,6,7,8-HxCDD ND 0.01000
I 1,2,3,7,8,9-HxCDD
Total HxCDD
ND
ND
0 01000
0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7.8-TCDD
I 1,2,3,4,7,8,9-HpCDF
Total HpCDF
ND
ND
0.01000
0.01000
Equivalence; 0.00024 ng/m2
(Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0150 0.01000 J
I Total HpCDD 0.0150 0 01000 J
OCDF ND 0.02000
OCDD 0.0920 0.02000 BJ
I Cone = Concentration (Totals include 2,3,7,8-substituted isomers)
LRL = Lower Reporting Limit
I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
I A = Detection Limit based on signal-to-noise measurement
J = Concentration detected is below the calibration range
B = Less than 10 times higher than method blank level
S = Saturated signal
ND = Not Detected
NA = Not Applicable
P = Recovery outside ot target range NC = Not Calculated
I Nn = Value obtained from additional analysis * = See Discussion
Report No ....02-1054210
I REPORT OF LABORATORY ANALYSIS