NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ceAnalvticaC__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax- 612- 607-6444 f
Client - ATC
Client's Sample ID ATC-0214-STY-DX4
Lab Sample ID 103331922
Filename U20306A_12
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/14/2002
ICAL Date 03/05/2002 Received 02/18/2002
CCal Filename{s) U20305B_16 & U20306A_17 Extracted 02/28/2002
Method Blank ID BLANK-1489 Analyzed 03/07/2002 00:10
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3.7.8-TCDF ND 0.0020 2,3.7,8-TCDF-13C 2.00 67
Total TCDF 0.011 0.0020 2,3,7,8-TCDD-13C 2.00 64
1.2,3,7.8-PeCDF-13C 2.00 75
2,3,7,8-TCDD ND 0.0027 A 2,3.4,7,8-PeCDF-13C 2.00 65
Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 72
1,2,3,4.7.8-HxCDF-13C 2.00 85
1,2,3,7.8-PeCDF ND 0.0100 1.2,3,6,7,8-HxCDF-13C 2.00 75
2,3,4,7,8-PeCDF ND 0.0100 2,3.4,6,7.8-HxCDF-13C 2.00 79
Total PeCDF ND 0.0100 1,2,3,7.8,9-HXCDF-13C 2.00 78
1,2,3,4,7,8-HxCDD-13C 2.00 84
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6.7,8-HxCDD-13C 2.00 73
Total PeCDD ND 0.0100 1,2,3,4,6.7,8-HpCDF-13C 2.00 81
1,2,3,4,7,8.9-HpCDF-13C 2.00 78
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 81
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 64
2,3,4,6.7.8-HxCDF ND 0.0100
1,2,3,7.8,9-HxCDF ND 0.0100 1,2.3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 76
1,2.3,6,7.8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.013 0.0100 J
1,2,3,4,6,7,8-HpCDF 0.038 0.0100 J Total 2,3.7,8-TCDD
1,2,3.4.7,8,9-HpCDF ND 0.0100 Equivalence; 0.0043 ng/m2
Total HpCDF 0.130 0.0100 (Using ITE Factors)
1.2,3,4,6,7,8-HpCDD 0.160 0.0100
Total HpCDD 0.260 0.0100
OCDF 0.120 0.0200
OCDD 2.200 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substttuted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
Report No.... 02-1054212
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003429586
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238270