^ceAnalytical''_________ Method 8290 Analysis Results
Tel: 612-607-1700
Fa*- 612- 607-6444
Client - ATC
Client's Sample ID ATC-0222-234M-DX2
Lab Sample ID 103343372
Filename U20311A_15
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/22/2002
ICAL Date 03/11/2002 Received 02/25/2002
CCal Filename(s) U20311A 07& U20311A_22 Extracted 03/05/2002
Method Blank ID BLANK-1499 Analyzed 03/11/2002 23:06
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND ---- 0.0033 A 2,3,7,8-TCDF-13C 2.00 78
Total TCDF ND ---- 0.0020 2,3,7,8-TCDD-13C 2.00 69
1,2.3.7,8-PeCDF-13C 2.00 82 N2
2.3,7,8-TCDD ND 0.0056 A 2,3,4,7,8-PeCDF-13C 2.00 79 *N2
Total TCDD ND 0.0020 1,2,3.7,8-PeCDD-13C 2.00 55 N2
1,2,3,4,7,8-HxCDF-13C 2.00 127
1,2.3,7,8-PeCDF ND 0.0100 1.2,3,6.7,8-HxCDF-13C 2.00 92
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 97
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 107
1,2,3,4,7,8-HxCDD-13C 2.00 119
1,2.3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 74
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 91
1,2,3,4,7,8,9-HpCDF-13C 2.00 100
1,2,3,4,7,8-HxCDF ND 0.0100 1.2,3,4,6,7,8-HpCDD-13C 2.00 95
1,2,3.6,7.8-HxCDF ND 0.0100 OCDD-13C 4.00 54 N2
2,3,4.6.7,8-HxCDF ' ND 0.0100
1.2,3,7,8,9-HxCDF ' ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1.2,3,4,7,8-HxCDD ND 0.0100 2,3.7,8-TCDD-37CI4 0.20 72
1,2,3,6.7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1.2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7.8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.000081 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6.7.8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.081 0.0200 BJ
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,B-substituted isomers) I = Interference
EMPC s Estimated Maximum Possible Concentration E = PCDE Interference
A a Detection Limit based on signal-to-noise measurement S = Saturated signal
J s Concentration detected is below the calibration range ND = Not Detected
B » Less than 10 times higher than method blank level NA = Not Applicable
P » Recovery outside ol target range NC = Not Calculated
Nn a Value obtained from additional analysis * = See Discussion