8290 Analysis Method Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client's Sample ID ATC-0222-234M-DX3
Lab Sample ID 103343380
Filename U20312A_08
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/22/2002
ICAL Date 03/12/2002 Received 02/25/2002
CCal Fiiename(s) U20312A 06&U20312A 21 Extracted 03/05/2002
Method Blank ID BLANK-1499 Analyzed 03/12/2002 16;02
Native Cone EMPC LRL Internal ng's Percent
isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND — 0.0020 2,3,7,8-TCDF-13C 2.00 72
TotatTCDF ND — 0.0020 2,3,7,8-TCDD-13C 2.00 67
1,2,3,7,8-PeCDF-13C 2.00 65
2,3,7,8-TCDD ND 0.0026 A 2,3,4,7,8-PeCDF-13C 2.00 69
Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 64 *
1,2,3,4,7,8-HxCDF-13C 2.00 75
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 70
2,3,4,7,8-PeCDF ND 0.0100 2,3,4.6,7,8-HxCDF-13C 2.00 74
Total PeCDF ND 0.0100 1,2,3.7,8,9-HxCDF-13C 2.00 75
1,2,3,4,7,8-HxCDD-13C 2.00 98
1,2,3,7,a-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 71
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 85
1,2,3,4,7,8,9-HpCDF-13C 2.00 86
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 100
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 78
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCD.F ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 69
1.2,3,6.7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1.2,3,4.6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD ND 0.0200
LRL = Lower Reporting Limit
Coflc = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC a Estimated Maximum Possible Concentration E = PCDE Interference
A ■ Detection Limit based on signal-to-noise measurement S = Saturated signal
J a Concentration detected is below the calibration range ND = Not Detected
B s Lass than 10 times higher than method blank level NA = Not Applicable
P s Recovery outside of target range NC = Not Calculated
Nn s Value obtained from additional analysis • = See Discussion
Report No.... 02-1054414
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002879180