NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________
Method 8290 Analysis Results
Tel: 612-507-1700
Fax- 61?- 607-6444
Client - ATC
Client's Sample ID ATC-0214-234M-DX2
Lab Sample ID 103331799
Filename U20302A_08
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/14/2002
ICAL Date 02/26/2002 Received 02/18/2002
CCal Filename(s) U20302A_01 &U20302A_17 Extracted 02/25/2002
Method Blank ID BLANK-1486 Analyzed 03/02/2002 22:15
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0020 2,3,7,8-TCDF-13C 2.00 88
Total TCDF 0.014 0.0020 2,3,7,8-TCDD-13C 2.00 77
1,2,3,7,8-PeCDF-13C 2.00 97
2,3,7,8-TCDD ND 0.0020 2,3,4,7,8-PeCDF-13C 2.00 88
Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 86
1,2,3,4,7,8-HxCDF-13C 2.00 92
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 81
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 74
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 86
1,2,3,4,7,8-HxCDD-13C 2.00 42
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 76
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 67
1,2,3,4,7,8,9-HpCDF-13C 2.00 82
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 63
1,2,3.6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 84 *
2,3,4,6,7,8-HxCDF ND 0.0100
1 ,2,3,7,8,9-HxCDP ND 0.0100 1,2,3.4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 52
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3.7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00011 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.010 0.0100 I
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.110 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1054209
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003444463
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000177799
OCR can misread numbers and units. Confirm readings against the page image before using them.