NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Indoor air quality report, M833, Feb 2002

Machine-extracted title · confidence 42%

IV notes on IAQ measurements collected for BOE program, Feb 2002.

NYC-WTC_000257035–000257038
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr Bernard P Orlan March 1,2002 Indoor Air Quality Assessment Page 3 H S of Economics and Finance fM833 ) ATCProiectNo 15-19125-0291

Real-Time Environmental Measurements

ATC collected one hundred forty-two (142) sets of real-time environmental measurements consisting of one hundred thirty-two (132) in the school building and nine (9) outdoors. Field data sheets are found in the Attachment Readings began at 8 11 A.M and concluded after 4 00 P M The results are described below

Temperature

Indoor dry bulb temperature measurements ranged from 54 5 °F to 71 3 °F One hundred twenty (120) of the measurements were below the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions) The outdoor temperature ranged from 32 to 57 6 °F

Relative Humidity

The relative humidity indoors ranged from 16 8 percent to 36 3 percent One hundred twenty­ eight (128) measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort All other measurements were below the ASHRAE recommended range The outdoor relative humidity ranged from 17 5 to 24.5 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 321 ppm to 1168 ppm. One (1) of the measurements was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level The outdoor (background) CO2 concentration was 411 ppm Therefore, the maximum acceptable level of CO2 at this location was nil ppm (background level + 700 ppm) The highest reading was found m room 706 (1168 ppm) at 8.56 AM with 24 occupants Levels above the recommended maximum do not indicate a health risk Carbon dioxide measurements are used as an mdicator of available outdoor air The primary source of CO2 indoors is occupant respiration

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors were 0 to 4 ppm These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm The outdoor CO concentration ranged from 0 to 4 ppm

Respirable Particulates (PM2 5}

Respirable particulate concentrations* indoors ranged between 0 pg/m^ to 25 pg/m^ with an average 6 pg/m^ None of the measurements were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter. The PM2 5 average concentration was also below the USEPA recommended concentration of 40 pg/m3 for sensitive individuals / children The outdoor respirable particulate concentration ranged from 1 pg/m3 to 43 pg/m^ with an average of 26 ug/m^

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average

CONFIDENTIAL, CITY_21MC100_003459435 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000257037

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000257037Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000297790

ATC IAQ report for Feb 13, 2002 at the referenced school.

Similar indexed content

NYC-WTC_000297808

ATC indoor air measurements report for February 14, 2002 at the school.

Similar indexed content

Compare copies and versions →