Mr Bernard P Orlan February 8, 2002 Indoor Air Quality Assessment Page 3 H S for Leadership & Pub. Service (M894) ATCProiectNo 15-19125-0290

Real-Time Environmental Measurements

ATC collected one hundred and forty (140) sets of real-time environmental measurements consisting of one hundred and thirty-four (134) in the school building and six (6) outdoors All fourteen floors of the school were surveyed Field data sheets are found in the Attachment Readings began at 8 00 A M. and concluded after 2.45 P.M. The results are described below

Temperature

Indoor dry bulb temperature measurements ranged from 64.6°F to 72.6°F Fifty-one (51) of the measurements were below the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions) The outdoor temperature range was 40 4°F to 45.1 °F.

Relative Humidity

The relative humidity indoors ranged from 23.8 percent to 39.1 percent. Seventy-nine (79) measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort The outdoor relative humidity range was 37.3. and 42.9 percent

Carbon Dioxide Concentrate

Carbon dioxide concentrations indoors ranged from 428 ppm to 1509 ppm Five (5) of the measurements were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations ranged from 412 ppm to 464 ppm Therefore, the maximum acceptable level of CO2 at this location was 1164 ppm (background level + 700 ppm). The highest reading was recorded m Room B-06, occupied by 17 people at around 10;30 A.M Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors were 1-2 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations were 1-3 ppm

Respirable Particulates (PM2 s)

Respirable particulate concentrations* indoors ranged between 7 pg/m^ to 43 pg/m^. None of the measurements were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter The outdoor respirable particulate concentrations ranged from 49 pg/m^ to 136 pg/m^ with an average of 92 pg/m3.

* The measurements made during this assessment were mstantaneous readings, the NPAAQS is a 24-hour average

CONFIDENTIAL, CITY_21MC100_007741179 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000256874

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000256874Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000297757

ATC quality report for IAQ measurements at a NYC high school in Feb 2002.

Similar indexed content

NYC-WTC_000297790

ATC IAQ report for Feb 13, 2002 at the referenced school.

Similar indexed content

NYC-WTC_000297826

ATC report of IAQ measurements collected Feb 15, 2002 at the referenced school.

Similar indexed content

NYC-WTC_000297808

ATC indoor air measurements report for February 14, 2002 at the school.

Similar indexed content

Compare copies and versions →