Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipe samples to be analyzed for lead content. Dust wipe samples were collected from representative unit ventilators within classrooms on north and south sides of the building. These locations are as follows:

• Room 1006 Room 640 • Room 938 Room 525 • Room 911 Room 451 • Room 826 Room 333 • Room 731 Room 251

The purpose of the sampling was to determine the lead content in the dust present within these unit ventilators. ATC’s representative Mr. Chacko Mathew visited Stuyvesant HS (M477) located at 345 Chambers Street, New York, NY on April 27, 2002.

Access holes were cut at the top of these units in order to reach the areas for sample collection. Samples were collected from behind the unit ventilators, adjacent to the intake grill installed within the building facade. The area from which the samples were collected are completely enclosed and are not accessible by building occupants.

LEAD-IN-DUST SAMPLING

Lead-in-dust threshold levels

The New York City Health Code, part 173.14, the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after lead abatement activity is achieved when dust wipe samples indicate lead levels below those listed below:

For Windowsills: 250 gg/tf For Floors: 40 gg/ft-

Although the lead-in-dust samples collected at Stuyvesant HS (M477) were not collected in response to lead abatement, these thresholds are referenced due to the fact that no other regulations or standards are applicable to this sampling.

Stuyvesant HS (M477) tiffins May 2, 2002

CONFIDENTIAL, CITY_21MC100_013441571 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000254816

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000254816Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →