Lead-in-dust wipe report, Stuyvesant HS, Mar 2002

Machine-extracted title · confidence 58%

Limited lead-in-dust wipe sampling report for Stuyvesant High School.

NYC-WTC_000336682–000336684
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were collected from areas specified by H.A. BADER Consultants, Inc. These areas are the following:

• Three classrooms per floor with unit ventilators on the North, East and South of the building.

The purposed of the dust wipe sampling is to determine if dust in the school contains lead. This additional dust wipe sampling was requested by H.A. BADER Consultants Inc. and it v/as approved by NYC-BOE.

ATC’s representative Mr. Yiannis Efstathiou visited Stuyvesant HS (M477) located at 345 Chamber Street, New York, NY on March 1“ 2002. Dust wipes to be analyzed for lead content were collected from the aforementioned areas indicated by H.A. BADER Consultants, Inc. and as specified by the New York City Board of Education Environmental Health & Safety Unit and in accordance with HUD protocols.

LEAD-IN-DUST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below:

For Windowsills: 250 gg/tf For Floors: 40 gg/ft^

Although the lead-in-dust samples collected at Stuyvesant HS (M477) were not collected in response to lead abatement, the same thresholds are used since no other regulations or standards are applicable to this project.

Sampling Methodology ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental

Stuyvesant HS (M477j (SftTC A E sc C lA T E I INC Afarch 4, 2002

CITY_21MC100_003072738

NYC-WTC_000336683

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000336683Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →