§ Long Island City REPORT OF AIR MONITORING
c
o
o
ro
New York, 11106
Tel: 718)729-1997
Fax: 718)729-1876
(PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS)
CLIENT: DCAS DATE: 10/03/01
“0
c
CT
o'
tn PROJECT: ADDRESS: 346 Broadway, Manhattan, NY "0
o> 12th, 11th, 9th, Sth, Sth, Sth, 4th, 2nd, 1st Floor, Lower Lobby
o
CD
CLIENT R W
FLOW FLOW SAMPLE FIBERS FIBERS 0
SAMPLE E O TIME TIME
LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID# O
ID# S R IN OUT O
(Ipm) (Ipm) (liters) FIELD CC c
P K 3
01 12th Floor - In Room East Wall By Windows 11:32 13:32 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A0110O4B-O1 o
3
02 12th Floor - East Room By South Stairs to the Roof 11:33 13:33 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A011004B-02
03 12th Floor - Elevators' Lobby______________________ 11:34 13:34 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-03
04 12th Floor - Broadway Side Office Middle Hallway 11:35 13:35 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-04
05 12th Floor - Office West Wall By Window__________ 11:36 13:36 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-05
06 11th Floor - Office East Side 11:52 13:52 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-06
07 11th Floor - East Hallway Middle___________________ 11:53 13:53 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-07
08 11th Floor - Elevator Lobby__________________ 11:54 13:54 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-08
09 11th Floor - West Side Hallway Middle_____________ 11:55 13:55 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A011004B-09
10 11th Floor - West Side Hallway____________________ 11:56 13:56 10 10 1200 0.060 <0.01 Air Quality (Immed. TAT) A011004B-10
11 9th Floor - East Hallway___________________________ 12:15 14:15 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-11
12 9th Floor - Elevator Lobby Waiting Room__________ 12:16 14:16 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-12
13 9th Floor - Hallway By Exit B_______________________ 12:18 14:18 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A011004B-13
14 9th Floor - West Hallway By Office_________________ 12:20 14:20 10 10 1200 0.070 < 0.01 Air Quality (Immed TAT) A011004B-14
15 Sth Floor - Reception Hallwa Tuberculosis Dept. 12:40 14:40 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A011004B-15
16 Sth Floor - Elevator Lobby_________________________ 12:41 14:41 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A011004B-16
17 Sth Floor - Hallway by Exit D_______________________ 12:45 14:45 10 10 1200 0.060 < 0.01 Air Quality (Immed. TAT) A011004B-17
18 Sth Floor - Hallway byRoom 810___________________ 12:46 14:46 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A011004B-18
19 Sth Floor - West Side Wali Office 12:48 14:48 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-19
20 Sth Floor - East Office Hallway_____________________ 13:14 15:15 10 10 1200 <0.055 ^0^ Air Quality (Immed. TAT) A011004B-20
21 6th Floor - East Hall Middle 13:16 15:16 10 10 1200 <0.055 < 0.01 Air Quality (Immed. TAT) A011004B-21
22 Sth Floor - Elevator Lobby_________________________ 13:17 15:17 10 10 1200 <0,055 <0.01 Air Quality (Immed. TAT) A011004B-22
23 Sth Floor - Classroom #3 13:18 15:18 10 10 1200 0070 <0.01 Air Quality (Immed. TAT) A011004B-23
TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY):
TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING,
5 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY):
O
SAMPLING TECHNICIAN: Z.B Nowak / M. Tchatchueng DATE RECEIVED: 10/04/01
H ROTAMETER: KAM- 04 DATE OF ANALYSIS: 10/04/01
I DATE OF REPORT: 10/04/01
Analyst: Lab Manager:
Deepak Bajracharya
The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area.
o
o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program.
I The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory.