Z KAM CONSULTANTS Z
o 35-40 36th Street o
co
g Long Island City REPORT OF AIR MONITORING
I
o NewYork.11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) ■D
O
O
Tel: (718)729-1997 c
CT
O
Fax:(718)729-1876 CLIENT: DCAS DATE: 10/04/01 o'
PROJECT: ADDRESS: 280 Broadway, Manhattan, NY ■D
00 o
KJ 7th & 6th Floor 3.
cn
CD
CLIENT
R w FLOW FLOW SAMPLE
QJ
SAMPLE LOCATION
E o TIME TIME
BEF. AFTER VOLUME
FIBERS FIBERS
PER PER
o
o
REMARKS LAB ID#
S R IN OUT o
ID# (Ipm) (Ipm) (liters) FIELD CC c
P K 3
01 7th Floor - East Corridor By Freight Elevator_________ 12:05 3:05 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A011005B-01 CD
02 7th Floor - South East Room By Elevator Exit 12:08 3:08 10~ 10 1800 <0055 <0,01 Air Quality (Immed. TAT) A011005B-02
03 7thFloor - South SideJdallwayJMiddle_______________ 12:11 sTi 1 10 10 1800 <0.055 <0,01 Air Quality (Immed. TAT) A011005B-03
04 7th Floor - South West ^ea Hallway 12:15 3:15 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A011005B-04
05 7th Floor - West Side Room in Front of Exit to Elevator 12:18 3:18 10 10 1800 <0,055 <001 Air Quality (Immed. TAT) A011005B-05
OS 7th Floor - Wes Side Hallway 12:22 3:22 10 10 1800 0.080 <0.01 Air Quality (Immed. TAT) A011005B-06
07 7th .Flopr- Hall-vay North Side CA Soft off West Wall 12:27 3:27 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A011005B-07
08 7th Floor - By A/C Room North Side 12:32^ 3:32 10 10 1800 <0,055 <0.01 Air Quality (Immed. TAT) A011005B-08
09 7th Floor - North Side Hallway Middle_______________ 12:37 3:37 10 10 1800 <0,055 <0.01 Air Quality (Immed. TAT) A011005B-09
10 7th Floor - North Side Hallway CA 50£t of Past Exit 12:40 3:40 10 10 1800 0,070 <0 01 Air Quality (Immed. TAT) A011005B-10
11 7th Floor - 30 Ft off East Exit North Hallway 12:45 3:45 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A011005B-11
12 7th Floor - Sout East Chambers Str. Room 12:50 3:50 10 10 1800 <0.055 <0 01 Air Quality (Immed. TAT) A011005B-12
13 6th Floor - East Corridor By Freight Elevator_________ 1:55 4:55 10 10 1800 0.080 <0.01 Air Quality (Immed. TAT) A011005B-13
14 6th Floor - East Corridor by Stairs C Exit 1:58 4:58 10 ■ 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A011005B-14
15 6th Floor - Hallway South / East Area_______________ 2:02 5:02 10 10 1800 <0 055 <0 01 Air Quality (Immed. TAT) A011005B-15
_16 6th Floor - Hallway Middle South Side 2:06 5:06 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A011005B-16
17 6th Floor - By South East Wall_____ 2:09 5:09 10 10 1800 0.060 <0.01 Air Quality (Immed. TAT) A011005B-17
18 6th Floor - By South Wall Middle 2:12 5:12 10 10 1800 <0 055 <0 01 Air Quality (Immed. TAT) A011005B-18
19 6th Floor - South West Corner Room 2:15 5:15 10 10 1800 <0.055 < 0.01 Air Quality (Immed. TAT) A011005B-19
20 6th Floor - By West Wall Middle Area 2:20 5:20 10 10 1800 <0.055 <0.01 Air Quality (Immed. TAT) A011005B-20
21 Sth Floor - North / West Area 2:25 5:25 10 10 1800 <0.055 < 0.01 Air Quality (Immed. TAT) A011005B-21
22 6th Floor - By Main Elevator Hallway North West 2:30 5:30 10 10 1800 <0.055 <0 01 Air Quality (Immed. TAT) A011005B-22
23 6th Floor - By /VC Room North Side 2:35 5:35 10 10 1800 <0,055 <0.01 Air Quality (Immed TAT) A011005B-23
TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY):
TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING,
6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY):
O
H SAMPLING TECHNICIAN. Z B Nowak / M. Tchatchueng DATE RECEIVED: 10/05/01
re ROTAMETER: KAV 04 DATE OF ANALYSIS: 10/05/01
I
KJ DATE OF REPORT: 10/08/01
Analyst: Lab Man
leepak Bajrachatya David Chen
o The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3, Ttie detection limit of this method is 7 fibers per square mm per filter area.
o
I KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program.
o
The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory.
co The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government.
co NYS-DOH ELAP 4 IJ273 AIHA » 100269
as 1