Air monitoring report header for Phase Contrast Microscopy analysis, undated

Machine-extracted title · confidence 90%

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

NYC-WTC_000178237–000178240
Page image
Scanned page image, NYC-WTC_000178238
OCR text

OCR status: ok · source: pdftotext

Z KAM CONSULTANTS Z

o 35-40 36th Street o Long Island City REPORT OF AIR MONITORING co § s o o NewYork, 11106 Tel: (718)729-1997 Fax:(718)729-1876 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) CLIENT: DCAS PROJECT: DATE: 09/26/01 “0 c CT o' ADDRESS: 2 Laffayette, Manhattan "0 00 22nd Floor, 16th Floor, 12th Floor, Sth Floor,4th Floor, & Main Lobby o KJ o R W 00 CLIENT FLOW FLOW SAMPLE FIBERS FIBERS SAMPLE LOCATION E o TIME TIME BEF. AFTER VOLUME PER PER REMARKS LAB ID# o o S R IN OUT o ID# P K (Ipm) (Ipm) (liters) FIELD CC c 3 01 22nd Floor - Corner Corridor Day Care By Elevators 18:00 20:00 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-01 o 3 02 22nd Floor - Stairway Y_________________________ 18:02 20:02, 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-02 03 22nd Floor - By Pantry 18:04 20:04 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-03 04 22nd Floor - By Stairwell W 18:06 20:06 10 10 1200 <0.055 10:01 Air Quality (Immed. TAT) A010927C-04 05 22nc Floor - A/C Room_________________________ 18:07 20:07 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-05 06 16th Floor - Corridor by Control Room 18:28(20^ 10 10 1200 0.070 <0.01 Air Quality (Immed. TAT) A010927C-06 07 16t.h Floor - Stairway Y 18:30 20:30 10 To 1200 0.060 <0.01 Air Quality (Immed. TAT) A010927C-07 ' oth Floor - Stairway W 18:32 20:32 10 lo 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-08 09 16th Floor - A/C Room 18:34 20:341 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-09 JO l^h FJoor - Efevator Lobby_____________________ 18:45 20:45 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-10 11 12th Floor - Stairwell Y 18:46 20:46 10 '10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-11 12 12th Floor - Corridor by Stairs W 18:48 20:48 10 ‘10’ 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-12 13 12th Floor - In A/C Room 18:50 20:50 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-13 14 5th Floor - Elevator Lobby______________________ 19:10 21:10 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-14 15 5th Floor - Corridor by Mens Restroom___________ 19:12 21:12 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-15 16 4th Floor - Corridor by Mens Bathroom___________ 19:22 21.22 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-16 17 4th Floor - By EleyatorJ.oW^_________________ 19:24 21:24 10 10 1200 0.060 <0.01 Air Quality (Immed. TAT) A010927C-17 'is' 4th Floor - By Main Entrance____________________ 19:26 21:26 10 10 1206 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-18 19 Main Lobby - Elevator Lobby 19:40 21:40 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-19 20 Main Lobby - By Main Entrance__________________ 19:41 21:41 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010927C-20 21 Field Blank____________________________________ <0.055 A010927C-21 2'2 Field Blank <0.055 AOI 0927C-22

TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY): TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING, 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): o SAMPLING TECHNICIAN: Z.B Nowak / M. Golembo/M.Tchatchueng DATE RECEIVED: 09/27/01 1"^ KJ

o o ROTAMETER: KAM- 04

Analyst: <f _ Deepak Bajracharya DATE OF ANALYSIS: 09/27/01 DATE OF REPORT: 09/27/01 Lab Manager: David Chen The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area. 1 o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program. I o The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory. 1 he report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. co co NYS-DOH ELAP It 11273 AIHA K 100269 on 1 CO

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000178238Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000178241

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178204

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178208

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178231

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

NYC-WTC_000178222

Document header identifying the project and laboratory performing phase contrast microscopy analysis of air filters for DCAS.

Similar indexed content

Compare copies and versions →