EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

References - 403

structures per square centimeter (s/cm^)

“BACKGROUND” If “ background” is defined as the level in a building less than 200 where there are no asbestos containing building materials, then background should be considered to be at or below 200 s/cm^. Testing of three government buildings in Maryland with no asbestos containing materials showed levels below 200 s/cm^.

A western state building with no asbestos containing materials had even less than 160 lower levels, an average mean concentration of 160 s/cm^.

“RECENTLY CLEANED HARD SURFACES” Bull dings with asbestos 86 to 320 containing materials where hard surfaces had been recently cleaned.

“LOW” Av erage of a wide range of measurement (6.5 to over 4.3 million 1000 s/cm^) for buildings with asbestos containing materials. This level was described as “low,” but not “background.” See the earlier entry in this table for levels inside buildings where no asbestos containing materials are used. If “background” is defined as the levels found in buildings not containing asbestos materials, then the “low" level of 1000 s/cm^ is high in comparison.

“ABOVE BACKGROUND” Levels that are considered to be definitively 10, Wili] above background

“HIGH” Lev els considered high and “in the range of a significant accidental 100, release from an abatement site”

50. US EPA (2003) FINAL DRAFT PILOT STUDY TO ESTIMATE ASBESTOS EXPOSURE fi-om VERMICULITE ATTIC INSULATION, Research Conducted in 2001 and 2002, Prepared for; Fibers and Organics Branch National Program Chemicals Division Office of Pollution Prevention and Toxics, U.S. Environmental Protection, Agency Ariel Rios Building 1200 Pennsylvania Avenue, N.W. Washington, D.C. 20460, Prepared by; Versar, Inc. 6850 Versar Center Springfield, VA 22151, May 21, 2003.

For web page to access all figures and tables in the report; http://WWW. epa. go v/opptintr/asbestos/insulationreport.pdf

51. See Table 6 of the EPA vermiculite attic study.

52. Interim Final WTC Residential Confirmation Cleaning Study, 110 Liberty St, New York, NY, 5/03, EPA Region 2, p. 4, footnote, http;//epa.gov/wtc/confirmation_clean_study.htm

The regulatory clearance criterion for TEM AHERA was 70 S/cm^, converted to 0.022 S/cc, based on a volume of 1200 cc.

NYC-WTC_000251559

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251559Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →