EPA memorandum on carpet asbestos testing, June 2002

Machine-extracted title · confidence 50%

Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.

NYC-WTC_000140127–000140137

Folder label: “EPA Cate Jenkins

Page image
Scanned page image, NYC-WTC_000140137
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

■ - «

Table 2. TYPICAL ASBESTOS DUST LEVELS INSIDE BUILDINGS^® Levels of asbestos found from testing of a large number of interiors with or without asbestos building materiate and/or asbestos contamination problems

structures per square centimeter (s/cm^)

“BACKGROUND” - If “background” is defined as the level in a building less than 200 where there are no asbestos containing building materials, then background should be considered to be at or below 200 s/cm^. Testing of three government buildings In Maryland with no asbestos containing materials showed levels below 200 s/cm^.

A western state building with no asbestos containing materials had even lower less than 160 levels, an average mean concentration of 160 s/cm^.

“RECENTLY CLEANED HARD SURFACES” - Buildings with asbestos 86 to 320 containing materials where hard surfaces had been recently cleaned.

“LOW” - Average of a wide range of measurement (6.5 to over 4.3 million 1000 s/cm^) for buildings with asbestos containing materials. This level was described as “low,” but not “background.” See the earlier entry in this table for levels inside buildings where no asbestos containing materials are used. If “background” is defined as the levels found in buildings not containing asbestos materials, then the “low” level of 1000 s/cm^ is high in comparison.

“ABOVE BACKGROUND” - Levels that are considered to be definitively 10,000 above background

“HIGH” - Levels considered high and “in the range of a significant accidental 100,000 release from an abatement site"

Appendix B shows that if a person were exposed over a lifetime to this level, the risk of cancer would be more than 2 in 1000. The AHERA TEM clearance test is also erratic and not reproducible, and the failure to use full aggressive conditions (leaf blower directed at all surfaces) can result in abnormally low readings. Thus, the use of K-factors, combined with the results of an ultrasonication test of carpet, or the ASTM 5755 microvacuum method for smooth surfaces, may provide a rough indicator of a potential for hazardous exposures.

As discussed in the following section, EPA’s Region 1 also uses these K-factors as a way of estimating asbestos air concentrations from settled dust levels. However, the values Region 1 inserted into the K-factor risk assessment formula were questionable for its year 2000 Brookfield, Connecticut School System risk assessment.

-11-

NYC-WTC_000140137

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000140137Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →