Potential health effects related to asbestos exposure. The nature of asbestos-related diseases; routes of exposure; dose-response relationships and the lack of a safe exposure level; the synergistic effect between cigarette smoking and asbestos exposure; the latency periods for asbestos-related diseases; a discussion of the relationship of asbestos exposure to asbestosis, lung cancer, mesothelioma, and cancers of other organs, [emphasis added\
Data showing background levels of asbestos in dust inside buildings
Because it is impossible to get away from all asbestos pollution because of the widespread past use of this material in brake linings, building insulation, etc., it is not realistic to clean up asbestos contamination to zero levels, even though this would be desirable. Cleaning up to background levels is the only solution. Under the CAA, all areas around an asbestos site must be tested and cleaned up so that there is no asbestos above background levels.^'
A widely accepted guideline for asbestos dust levels in relation to background is given in Table 2. If “background level” is defined as the dust levels inside buildings where no asbestos containing materials are used, then the level is less than 200 asbestos structures per square centimeter of surface area (s/cnr). There are also levels categorized as low, above background, and high, based on measurements of a large number of surfaces inside buildings.
Estimating air concentrations and risks from settled dust levels
When air concentrations are unknown, or when available air testing is not sensitive enough to detect asbestos at the extremely low levels relsted to cancer, it is possible to use settled dust levels as a way of predicting air levels. Appendix A provides a chart for estimating air levels of asbestos from measured asbestos levels in settled dusts. Appendix B provides a chart relating air levels to cancer lisks.
This method is widely recognized. It is used not only in the field of asbestos, but also for dusts containing other toxic substances such as lead, beryllium, uranium particles, alpha emitters, radioactive iodine, zinc sulfur powder, and microorganisms.^^ It involves using experimentally determined ratios of levels in surface dusts to air levels, depending on the amount of human activity that would stir up the dusts. These ratios are called “K-factors”.
The air test that EPA is providing, the AHER/l TEM clearance test, is not sensitive enough to measure asbestos at the very low concentrations that can cause asbestos-related diseases such as lung cancer, mesothelioma, and asbestosis. The “passing” level of 70 structures per square millimeter is the same as about 0.01 PCM-equivalent fibers per milliliter (PCM fZmL).
- 10-
CITY_21MC100_002847466
NYC-WTC_000209436
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
15 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
13 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151635
EPA memorandum detailing plans for asbestos wipe sampling, projecting airborne dust levels, and estimating increased cancer risks from WTC dust exposure.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140259
Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154652
Internal tracking document for managing reports, comments, and actions related to environmental compliance cases.
11 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140235
Memorandum comparing asbestos data in Manhattan to other sites and arguing for cleanup under the Superfund statute.
11 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
11 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094469
Letter from Enviroscience Consultants providing air and bulk sampling results for 86 Trinity Place.
5 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similar indexed content
NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similar indexed content
NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Similar indexed content
NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
Similar indexed content
NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similar indexed content