NYC-WTC_000275438
EPA memorandum describing ultrasonication carpet dust test method for asbestos.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗EPA memo documenting issues with asbestos testing standards post-WTC collapse.
NYC-WTC_000250730–000250772OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
70 s/mm^ is not the AHERA standard, as explained in the AHERA regulations themselves
It is a LABORATORY BACKGROUND, the same as a DETECTION LIMIT or lab SENSITIVITY
A "LABORATORY BACKGROUND" is like going to a salad bar with a container for the salad.
The scale at the cashiers is good for weighing the large amount of salad, because the weight of the container is relatively small.
But if you went to the cashiers with an empty container and asked that it be weighed for traces of cyanide, you would be out of luck, since the cyanide would weigh much less than the container.
The container for the salad is like a "LABORATORY BACKGROUND"
In their naivete of analytical testing methods, Region 2 is under the mistaken belief that 70 s/mm^ is the natural, typical background level of asbestos in normal air. Region 2 states this explicitly, seen in the excerpts in the preceding section.
EPA Region 2 has unfortunately completely misinterpreted the regulations at Title 40 of the Code of Federal Regulations, which describe in detail the meaning of the 70 s/mm^ level for the AHERA TEM clearance test.
It is only the detection limit of a particular air test for asbestos, or the sensitivity of the method, a LABORATORY BACKGROUND. The word “background” refers to the fact that one particular filter material through which air is drawn is already contaminated with asbestos.
Analysts have the choice of using either polycarbonate filters or methyl cellulose filters. Polycarbonate filters have asbestos fibers in the filter material itself. The AHERA clearance test was designed to allow for the presence of the asbestos in the polycarbonate filters, so it set the level at 70 s/mm" to allow for this contamination. Typically, the methyl cellulose filters are used today because it is understood that using polycarbonate filters would result in finding some asbestos as part of the lab background. Using methyl cellulose filters gives a “free pass” of 70 s/mm“.
Extensive excerpts are given of the AHERA regulations, which make it very clear that 70 s/mm^ only refers to the detection limit or sensitivity or laboratory background of the AHERA TEM clearance test. Nowhere in the AHERA regulations is the word “standard” or “safe” used in conjunction with 70 s/m\ In fact, in the next section, it can be seen that the same AHERA regulations state that there is NO safe exposure to asbestos.
-8-
CITY_21MC100_013381557
NYC-WTC_000250737
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000275438
EPA memorandum describing ultrasonication carpet dust test method for asbestos.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436441
EPA memorandum describing ultrasonication carpet testing for asbestos; guidance and benchmarks.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
11 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448293
Memorandum describing EPA ultrasonication method for carpet asbestos testing.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452613
EPA memorandum describing ultrasonication carpet/asbestos testing method.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430642
EPA memo on ultrasonication carpet testing for asbestos reservoirs and findings.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451143
EPA memo describing ultrasonication method for carpet/asbestos testing.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433176
EPA memorandum describing ultrasonication test method for asbestos in carpets.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453034
EPA memo describing ultrasonication method for asbestos in carpets.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418123
EPA memo describing ultrasonication method for asbestos in carpets and fabrics.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000251148
Comments on EPA interim report regarding World Trade Center collapse from 2003.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251148
Comments on EPA interim report regarding World Trade Center collapse from 2003.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140235
Memorandum comparing asbestos data in Manhattan to other sites and arguing for cleanup under the Superfund statute.
Similarity score 0.955 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251148
Comments on EPA interim report regarding World Trade Center collapse from 2003.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251148
Comments on EPA interim report regarding World Trade Center collapse from 2003.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Similar indexed content
NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similar indexed content
NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similar indexed content
EPA memorandum describing ultrasonication carpet dust test method for asbestos.
Similar indexed content
NYC-WTC_000448293
Memorandum describing EPA ultrasonication method for carpet asbestos testing.
Similar indexed content