70 s/mm^ is not the AHERA standard, as explained in the AHERA regulations themselves

It is a LABORATORY BACKGROUND, the same as a DETECTION LIMIT or lab SENSITIVITY

A "LABORATORY BACKGROUND" is like going to a salad bar with a container for the salad.

The scale at the cashiers is good for weighing the large amount of salad, because the weight of the container is relatively small.

But if you went to the cashiers with an empty container and asked that it be weighed for traces of cyanide, you would be out of luck, since the cyanide would weigh much less than the container.

The container for the salad is like a "LABORATORY BACKGROUND"

In their naivete of analytical testing methods, Region 2 is under the mistaken belief that 70 s/mm^ is the natural, typical background level of asbestos in normal air. Region 2 states this explicitly, seen in the excerpts in the preceding section.

EPA Region 2 has unfortunately completely misinterpreted the regulations at Title 40 of the Code of Federal Regulations, which describe in detail the meaning of the 70 s/mm^ level for the AHERA TEM clearance test.

It is only the detection limit of a particular air test for asbestos, or the sensitivity of the method, a LABORATORY BACKGROUND. The word “background” refers to the fact that one particular filter material through which air is drawn is already contaminated with asbestos.

Analysts have the choice of using either polycarbonate filters or methyl cellulose filters. Polycarbonate filters have asbestos fibers in the filter material itself. The AHERA clearance test was designed to allow for the presence of the asbestos in the polycarbonate filters, so it set the level at 70 s/mm" to allow for this contamination. Typically, the methyl cellulose filters are used today because it is understood that using polycarbonate filters would result in finding some asbestos as part of the lab background. Using methyl cellulose filters gives a “free pass” of 70 s/mm“.

Extensive excerpts are given of the AHERA regulations, which make it very clear that 70 s/mm^ only refers to the detection limit or sensitivity or laboratory background of the AHERA TEM clearance test. Nowhere in the AHERA regulations is the word “standard” or “safe” used in conjunction with 70 s/m\ In fact, in the next section, it can be seen that the same AHERA regulations state that there is NO safe exposure to asbestos.

-8-

CITY_21MC100_013381557

NYC-WTC_000250737

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250737Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →