Reporting TEM air measurements in either "structures/square millimeter" or
"structures/milliliter"
To complicate things further, in the WTC disaster, EPA's web site21 has only been reporting
TEM measurements in the units of "structures/square millimeter" (.s/mm2 ), which IS NOT THE
SAME as "structures/milliliter ( s/mL )". The actual lab sheets, which were obtained by a
Freedom of Information Act request and pos :d at the New York Environmental Law and Justice
Projzct web site22 gave the asbestos levels in both units.
The "structures/mm2 " unit refers to the number of structures on a given area of a filter through
which the air drawn. There is no easy way to convert "structures/square millimeter" to
"fibers/millilitei"unless you have the volume of air sampled from the original lab sheet. This is
because you need the air volume to convert fibers/millimeter to fibershnilliliter, and this volume
is not always the same. Any level reported as structures/square millimeter will always be much
higher than the structures/milliliter, usually by a factor of at least 100.
The "70 structures or less" AHERA clearance standard for air
In the World Trade Center disaster, EPA has said that it is using the level of 70 or fewer
asbestos structures/square millimeter standard required by the Asbestos Hazard Emergency
Response Act (AHERA). This 70 or fewer structures does not correspond to any level found to
be related to health effects. Instead, it is the equivalent to detecting 4 structures in 10 TEM grid
openings in a filter through which air has been drawn.
The AHERA "Standard" for clearance is - "A response action is determined be completed by
to
TEM when the abatement area has been cleaned and the airborne asbestos concentration inside
the abatement area is no higher than concentrations at locations outside the abatement area." The
70 structures criterion is an intermediate standard designed to reduce the number of analyses (and
costs) by stating that if the average loading on the five samples collected inside the abatement
does not exceed 70 structures.mm2, the samples are below filter backgrounds and there is no neel
to analyze the five outside samples and perform the "Z-test."
The filters used collect the asbestos in air are always contaminated with low levels of asbestos.
to
The :fibers found as background on the filter were present without any air being drawn through
the filter. Thus, this 70 structures/square millimeter corresponds roughly to a general laboratory
method background level of 0.02 structures/milliliter.
"cc" land "mL" are the same thing. "um" and "am" are the same thing
Milliliters (mL) are the same as cubic centimeters (cc). Air concentrations are sometimes
reported using cubic centimeters instead of milliliters, as in "fibers/cc" or "fibers/mL".
Micrometers are abbreviated either as "µm" with the Greek " µ "or as " um".
- 17-
NYC-WTC 000125950