Reporting TEM air measurements in either “structures/square millimeter” or “structures/milliliter”

To complicate things further, in the WTC disaster, EPA’s web site^' has only been reporting TEM measurements in the units of “structures/square millimeter” ( s/mm^), which IS NOT THE SAME as “structures/milliliter ( s/mL)”. The actual lab sheets, which were obtained by a Freedom of Information Act request and posted at the New York Environmental Law and Justice Project web site^^ gave the asbestos levels in both units.

The “structures/mm^" unit refers to the number of structures on a given area of a filter through which the air drawn. There is no easy way to convert “structures/square millimeter” to “fibers/millilitef’unless you have flie volume of air sampled from the original lab sheet. This is because you need the air volume to convert fibers/millimeter to fibers/milliliter, and this volume is not always the same. Any level reported as structures/square millimeter will always be much higher than the structures/milliliter, usually by a factor of at least 100.

The “70 structures or less” AHERA clearance standard fw air

In the World Trade Center disaster, EPA has said that it is using the level of 70 or fewer asbestos structures/square millimeter standard required by the Asbestos Hazard Emergency Response Act (AHERA). This 70 or fewer structures does not correspond to any level found to be related to health effects. Instead, it is the equivalent to detecting 4 structures in 10 TEM grid openings in a filter through which air has been drawn.

The AHERA “Standard” for clearance is - “A response action is determined to be completed by TEM when the abatement area has been cleaned and the airborne asbestos concentration inside the abatement area is no higher than concentrations at locations outside the abatement area.” The 70 structures criterion is an intermediate standard designed to reduce the number of analyses (and costs) by stating that if the average loading on the five samples collected inside the abatement does not exceed 70 structures.mm\ the samples are below filter backgrounds and there is no need to analyze the five outside samples and perform the “Z-test.”

The filters used to collect the asbestos in air are always contaminated with low levels of asbestos. The fibers found as background on the filter were present without any air being drawn through the filter. Thus, ftiis 70 structures/square millimeter corresponds roughly to a general laboratory method background level of 0.02 structures/milliliter.

“cc” and “mL” are die same thing, “um” and “um” are the same thing

Milliliters (mL) are the same as cubic centimeters (cc). Air concentrations are sometimes reported using cubic centimeters instead of milliliters, as in “fibers/cc” or “fibers/mL”.

Micrometers are abbreviated either as ‘Vm” with the Greek “ p ” or as “ um”.

- 17-

NYC-WTC_000154670

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000154670Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →