Reporting TEM air measurements in either "structure square millimeter" or
"structures/milliliter"
To complicate things further, in the WTC disaster, EPA's web site21 has only been reporting
TEM measurements in the units of "structures/square millimeter" (s/mm2 ), which IS NOT
THE
SAME as "structures/milliliter ( s/mL )". The actual lab sheets, which were obtained by a
Freedom of Information Act request and pos :d at the New York Environmental Law and
Justice
Project web site22 gave the asbestos levels in both units.
The "structures/mm2 " unit refers to the number of structures on a given area of a filter
through
which the air drawn. There is no easy way to convert "structures/square millimeter" to
"fibers/millilitef'unless you have the volume of air sampled from the original lab sheet. This is
because you need the air volume to convert fi bers/millimeter to fibers/milliliter, and this
volume
is not always the same. Any level reported as structures/square millimeter will always be
much
higher than the structures/milliliter, usually by a factor of at least 100.
The "70 structures or less" AHERA clearance standard for air
In the World Trade Center disaster, EPA has said that it is using the level of 70 or fewer
asbestos structures/square millimeter standard required by the Asbestos Hazard Emergency
Response Act (AHERA). This 70 or fewer structures does not correspond to any level
found to
be related to health effects. Instead, it is the equivalent to detecting 4 structures in 10
TEM grid
openings in a filter through which air has been drawn.
The AHERA "Standard" for clearance is - "A response action is determined to be
completed by
TEM when the abatement area has been cleaned and the airborne asbestos concentration
inside
the abatement area is no higher than concentrations at locations outside the abatement
area." The
70 structures criterion is an intermediate standard designed to reduce the number of
analyses (and
costs) by stating that if the average loading on the five samples collected inside the
abatement
does not exceed 70 structures.mm2, the samples are below filter backgrounds and there is
no nee:
to analyze the five outside samples and perform the "Z-test."
The filters used to collect the asbestos in air are always contaminated with low
levels of asbestos.
The =fibers found as background on the filter were present without any air being drawn
through
the filter. Thus, this 70 sttuctures/square millimeter corresponds roughly to a general
laboratory
method background level of 0.02 structures/milliliter.
"cc" and "mL" are the same thing, "um" and "am" are the same thing
Milliliters (mL ) are the same as cubic centimeters (cc). Air concentrations are
sometimes
reported using cubic centimeters instead of milliliters, as in "fibers/cc" or "fibers/mL".
Micrometers are abbreviated either as "µm" with the Greek " µ "or as "urn".
- 17-
NYC-WTC 000125988