EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

J: AIR TESTING AND STANDARDS FOR ASBESTOS “Did people receive enough information about air quality? ... some missed subtleties of EPA’s intended message ,..

“The AHERA ‘standard’ used to conclude that asbestos levels were safe is not a health-based standard. AHERA standard based on minimum detection limit that used old filters (70 structures/mm^);" new filters capable of achieving lower detection limits of approx. 15 s/cc.” [1/27/03 EPA IG report]

AHERA clearance test not a safe level or benchmark - EPA IG report correct

The following statement was in the EPA IG report of 1/27/03:

The AHERA “standard” used to conclude that asbestos levels were safe is not a health­ based standard. AHERA standard based on minimum detection limit that used old filters (70 structures/cc):*’ new filters capable of achieving lower detection limits of approx. 15 s/cc.. . . [1/27/03 EPA IG report]

EPA’s Office of Research and Development made the same statement in their 10/02 draft risk assessment for the WTC:

The principal benchmark used in this assessment for evaluation of asbestos in air data from the WTC site is the Asbestos Hazard Emergency Response Action (AHERA) standard of 70 S/mm^.... It should be noted that this standard is not health based, but rather technology based. It is also noted that the technology has improved since 1987, such that current filters often have much less than 17.5 S/mm^ sometimes close to 0 S/mm^. Therefore, 70 S/mm^ would be much higher than blanks and represents more than just a statistical elevation above background, above. Finally it is noted that while the AHERA standard was originally intended as an indoor ‘clearance’ standard, it is being used to evaluate outdoor exposures in this assessment.

[Exposure and Human Health Evaluation of Airborne Pollution from the World Trade Center Disaster, External Review Draft, 10/02, National Center for Environmental Assessment, Office of Research and Development, EPA, Publication Nos. NCEA - W- 1395, or EP/\/600/P-2/002A, http://www.epa.gov/ncea or http://oaspub.epa.gov/eims/eimscomm.getfile?p_download_id=36387 ]

EPA and NYC claims that AHERA 70 s/mm^ level is a health standard

The following ate official statements both by EPA and the NYC Departments of Environmental Protection and Health claiming that the AHERA level of 70 structures per square millimeter (70

NYC-WTC_000251347

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251347Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →