OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

sufficiently low so that it cannot be distinguished from the filteT contamination/background level (fibers deposited on the filter that are unrelated to the air being sampled).

The initial screening test is expressed in structures per square millimeter of filter because filter background levels come from sources other than the air being sampled and cannot be meaningfully expressed as a concentration per cubic centimeter of air. The value of 70 s/mm^ is based on the experience of the panel of microscopists who consider one structure in 10 grid openings (each grid opening with an area of 0.0057 mm^) to be comparable with contamination/background levels of blank filters. The decision is based, in part, on Poisson statistics which indicate that four structures must be counted on a filter before the fiber count is statistically distinguishable from the count for one structure. [emphasis added]

[The Code of Federal Regulations are available from most larger libraries, all law libraries, and also online at: http://www.access.gpo.gov/nara/cfi7index.html, or for EPA-only (iaster) at http://www.epa.gov/epahome/cfr40.htm ]

It is true that EPA Region 2's air tests in Manhattan had greater sensitivity than 70 s/mm^. That is because they used methyl cellulose filters, which do not have the asbestos contamination problem.

Region 2 mistakes 70 s/mm^ as a normal air "background" level

Regional Counsel for EPA’s Region 2 exj^lained his belief of the meaning of 70 s/mm^. He believes that it is a normal air background, and when the AHERA clearance test is run, the results of the test are COMPARED WITH the 70 s/mm^ “background” level:

These rules include what is commonly called a clearance test ... The specified AHERA clearance test procedure includes, inter alia, a step in which air monitored in the affected space is compared with the specified “background” level of 70 structures per square millimeter (70 s/mm

[Mugdan, Walter E., Esq. (January 25, 2002) Environmental law issues raised by terrorist events in 2001. Speech before the NY Bar Association. Posted at www.NYenviroLAW.org 1

This is wrong. There is no comparison going on at all with the results of the test and any purported background level of 70 s/nim“. Instead, the AHERA TEM clearance test requires a comparison with the actual background air, which must be done by sampling the air outside and actually testing it, according to the procedures of the AHERA test.

As seen above, the word “background” in the regulations refers to a. laboratory background from unavoidable asbestos contamination of the filter through which air is drawn.

- 10-

CITY_21MC100_013381559

NYC-WTC_000250739

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250739Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →