NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Lab analysis report, Pace Analytical, 19125-0279

Machine-extracted title · confidence 52%

PACE report header stating lab analysis and project details for sample set 19125-0279.

NYC-WTC_000249395–000249409
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 weAnalyticar www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Minneapolis: MN 55414 Phone: 612.607.1700 Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: January 3, 2002

PAGE: 7 REPORT NO: 01-1052125

Quality Control

The performance of the sample processing steps and the instrumentation are monitored on a routine basis. The procedures and criteria are summarized below.

One method blank and one laboratory spike sample are typically prepared with each ten samples of any given matrix. The recoveries of the native PCDD and PCDF analytes in the laboratory spike samples generally range from 70 to 130%. Recoveries of selected analytes outside this range do not invalidate the data but provide information which is used by the laboratory to monitor recovery trends and to assure optimization of the method.

Internal standards are spiked into each sample prior to extraction in order to monitor the level of recovery which is achieved for each individual sample. Acceptable recoveries range from 40 to 1 35 percent unless a deviation is due to variation in instrument response as a result of analytical interferences.

The resolution of the mass spectrometer is verified prior to each analysis to be 10,000 or greater. Hardcopies of the reference peaks are printed at the beginning and end of each analysis day. The resolving power of the DB-5 chromatographic column is checked daily by analyzing a standard solution containing 2,3,7,8-TCDD and the adjacent TCDD isomers. Acceptable performance is achieved when 2,3,7,8-TCDD is resolved from the adjacent isomers by a valley of 25% or less. The group times for the selected-ion-monitoring data acquisitions are also checked daily by analyzing the column performance mix which has been modified to contain the first and last eluting isomers of each congener class. In this way one is assured of collecting data representative of the total PCDD and PCDF content and that the 2,3,7,8-substituted isomers are suitably resolved.

Initial calibrations are generated by analyzing standard solutions (see Table 4) containing target native and labeled PCDD and PCDF compounds. Response factors are calculated and averaged for each compound. These averages are used for quantification and for comparison to the daily continuing calibration. Acceptable ranges are specified in Method 23. A continuing calibration standard is analyzed at the beginning of each 1 2-hour shift on days when initial calibrations are not performed. The initial calibration is considered to be valid when the response factors from the continuing calibration analysis agree to within the ranges specified in Method 23.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CONFIDENTIAL, CITY_21MC100_003444498 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000249402

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000249402Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000396324

Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.

Similar indexed content

NYC-WTC_000395823

Pace Analytical chain-of-custody form, project data and page count note.

Similar indexed content

NYC-WTC_000396381

PACE chain-of-custody accompanying a 30-page Pace Analytical report package.

Similar indexed content

Compare copies and versions →