NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Chain-of-custody, Pace Analytical, 30 pages

Machine-extracted title · confidence 34%

PACE chain-of-custody accompanying a 30-page Pace Analytical report package.

NYC-WTC_000396381–000396395
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200

3 ^ace Analytical' Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

□ PROJECT: PCDD/PCDF ANALYSES DATE: December 20, 2001

PAGE: 7 REPORT NO: 01-1052010

_ Quality Control

The performance of the sample processing steps and the instrumentation are monitored on a routine basis. The procedures and criteria are summarized below.

One method blank and one laboratory spike sample are typically prepared with each ten samples of „ any given matrix. The recoveries of the native PCDD and PCDF analytes in the laboratory spike ’52 samples generally range from 70 to 130%. Recoveries of selected analytes outside this range do not invalidate the data but provide information which is used by the laboratory to monitor recovery ._ trends and to assure optimization of the method.

Internal standards are spiked into each sample prior to extraction in order to monitor the level of recovery which is achieved for each individual sample. Acceptable recoveries range from 40 to sJ 135 percent unless a deviation is due to variation in instrument response as a result of analytical interferences.

The resolution of the mass spectrometer is verified prior to each analysis to be 10,000 or greater. Hardcopies of the reference peaks are printed at the beginning and end of each analysis day. The resolving power of the DB-5 chromatographic column is checked daily by analyzing a standard j solution containing 2,3,7,8-TCDD and the adjacent TCDD isomers. Acceptable performance is achieved when 2,3,7,8-TCDD is resolved from the adjacent isomers by a valley of 25% or less. The group times for the selected-ion-monitoring data acquisitions are also checked daily by - 9 analyzing the column performance mix which has been modified to contain the first and last eluting isomers of each congener class. In this way one is assured of collecting data representative of the total PCDD and PGDF content and that the.2,3,7,8-substituted isomers are suitably resolved.......

Initial calibrations are generated by analyzing standard solutions (see Table 4) containing target "'j native and labeled PCDD and PCDF compounds. Response factors are calculated and averaged for — each compound. These averages are used for quantification and for comparison to the daily continuing calibration. Acceptable ranges are specified in Method 23. A continuing calibration ; standard is analyzed at the beginning of each 12-hour shift on days when initial calibrations are not performed. The initial calibration is considered to be valid when the response factors from the continuing calibration analysis agree to within the ranges specified in Method 23.

REPORT OF LABORATORY ANALYSIS This report shall riot be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CITY_21MC100_002891283

NYC-WTC_000396388

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000396388Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000395823

Pace Analytical chain-of-custody form, project data and page count note.

Similar indexed content

NYC-WTC_000396324

Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.

Similar indexed content

NYC-WTC_000395804

Chain-of-Custody data sheet for Pace Analytical project 6526-0279.

Similar indexed content

NYC-WTC_000396362

Pace Analytical chain-of-custody form accompanying a 31-page lab report package.

Similar indexed content

NYC-WTC_000395785

Chain-of-Custody document for Pace Analytical lab data and pages count.

Similar indexed content

Compare copies and versions →