NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ^ace Analytical’ Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: January 3, 2002

PAGE: 6 REPORT NO: 01-1052125

Quantification and Calculations (Cont.)

Each pair of ion mass peaks in the selected-ion-current chromatograms was evaluated manually to determine if it met the criteria for a PCDD or PCDF isomer. Areas of all peaks exhibiting correct ion ratios and having retention times within the correct windows were then summed for calculations of total congener concentrations. The 2,3,7,8-TCDD toxic equivalency factors (TEFs) used to calculate the sample toxic equivalency are listed in Table 5.

A limit of detection (LOD) based on producing a signal that is 2.5 times the noise level, was calculated for each undetected 2,3,7,8-substituted isomer. The noise heights used to calculate the detection limits were measured at the retention time of the specific isomer. The formula used for calculating the LOD is:

Hn X Qis X 2.5 LOD = His X Rf where:

LOD Single isomer limit of detection Hn Sum of noise heights at native isomer retention time Qis Quantity of labeled internal standard His Sum of peak heights for labeled internal standard Rf Response factor

The recoveries of the labeled surrogate compounds, relative to the corresponding internal standard, and the ’^Cij-labeled internal standards, relative to either 1,2,3,4-TCDD-’®Ci2 or 1,2,3,7,8,9- HxCDD-^^Ci2, were calculated using the following equation:

Ais X Qrs x 100% %R = Rfr X Ars x Qis where:

%R = Percent recovery of labeled internal standard Ais Sum of integrated areas of labeled internal standard Qrs Quantity of recovery standard Ars Sum of integrated areas of recovery standard Rfr Response factor of the specific labeled internal standard relative to the recovery standard Qis Quantity of the labeled internal standard added to the sample

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CONFIDENTIAL, CITY_21MC100_003444497 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000249401

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000249401Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000396324

Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.

Similar indexed content

NYC-WTC_000395823

Pace Analytical chain-of-custody form, project data and page count note.

Similar indexed content

NYC-WTC_000396381

PACE chain-of-custody accompanying a 30-page Pace Analytical report package.

Similar indexed content

Compare copies and versions →