Lab analysis report, Pace Analytical, 19125-0279

Machine-extracted title · confidence 52%

PACE report header stating lab analysis and project details for sample set 19125-0279.

NYC-WTC_000249395–000249409
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 weAnalyticar Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: January 3, 2002

PAGE: 5 REPORT NO: 01-1052125

Quantification and Calculations

The PCDD and PCDF isomers were quantified by comparison of their responses to the responses of the labeled internal standards as described in USEPA Method 23. Relative response factors were calculated from analyses of standard mixtures containing representatives of each of the PCDD/PCDF congener classes at five concentration levels, and each of the internal standards at one concentration level, as shown in Table 4. The PCDD/PCDF response factors were calculated by comparing the sum of the responses from the two ion masses monitored for each chlorine congener class to the sum of the responses from the two ion masses of the corresponding isotopically labeled internal standard. The formula for the response factor calculation is:

An X Qis Rf = Ais X Qn

where:

Rf Response factor An Sum of integrated areas for native isomer Qis Quantity of labeled internal standard Ais Sum of integrated areas for labeled internal standard Qn Quantity of native isomer

The levels of PCDDs and PCDFs in each sample were quantified using the following equation:

An X Qis C = Ais X Rf

where:

C = Concentration of target isomer or congener class An = Sum of integrated areas for the target isomer or congener class Qis = Quantity of labeled internal standard added to the sample Ais = Sum of integrated areas for the labeled internal standard . Rf = Response factor

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in lull, without the written consent of Pace Analytical Services, Inc.

nebc- CONFIDENTIAL, CITY_21MC100_0 03444496 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000249400

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000249400Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000396324

Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.

Similar indexed content

NYC-WTC_000395823

Pace Analytical chain-of-custody form, project data and page count note.

Similar indexed content

NYC-WTC_000396381

PACE chain-of-custody accompanying a 30-page Pace Analytical report package.

Similar indexed content

Compare copies and versions →