Lead and metal concentrations, building 7 samples

Machine-extracted title · confidence 24%

Table of metal concentrations from field samples, with various metals listed and results.

NYC-WTC_000246819
Page image
Scanned page image, NYC-WTC_000246819
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Metal Aerosol Concentrations (slide 2) Personal Sample Mounted Personal Sample Mounted Metal on Basket Suspended from on “Bay Crane” at B!dg.#7 Crane Bldg.#7 (p,g/m’) _________ (jJg/uT)_________ Lead 1105) ____________ 5T____________ Magnesium _______ 61 Manganese _________ <0,5_________ _________ <0,5_________ Nickel ............. .. <0.5_________ _________ <0A_________ Potassium __________ 2.3________ _ 1.1 Selenium _________ <0^_________ _________ <0.5_________ Silver <0,5 __________ <0,5_________ Sodium 260 260 Thallium <0.5 <0.5 Vanadium 4.5 0.56 Zinc 34 120 © H? EnxdronmentaL Inc. 2001

VOC in Air Concentrations (slide 1) Surrogate Personal Sample tfi SuiTogate Personal Sample #1 (23.8 liters of air, morning) (1.83 liters of air, aftenioon) Volatile Organic Compound Mounted on “Bay Crane” at Mounted on “Bay Crane” at Bldg.#7(us/ni’) Bld.g.#7 (Mg/m^) Benzene 1.8(57) ND Camphene ND 8.8 Decafie 0.6 ND Dichlorobeiizene, 1,4- 0.1 12.6 Dodecane 0.5 ND Ethylbenzene 3.6 (33) 10.2 Guanosine, 2'-O-methyl- ND 31.9 Linionene 0.6 9.6 Methylene Chloride 0.1 29.5 Melhvlethvthenvme l- I.O ND

Compounds listed in italic are considered tentatively identified by quality ma.ss spectra. Quantitation of diese HCs are sstimaF’s based on relath'e response equivalent against toluene sisndarii. Quaniiiaiionof identified VOCs are based on a 5 point calibration curve for each compound con.«iistent with EPA method 8260. Concentrations listed in parentheses aie values derived from air collected during the morning and a ftemoon sampling period on a charcoal lube and analyzed by GC/FID consistent with NIOSH method 1500. © HP Environmental, Inc. 2001

Copyright © HP Environmental, Inc. 2001 / All rights reserved. 1

CONFIDENTIAL, CITY_21MC100_009889989 SUBJECT TO PROTECTIVE ORDER NO.3, JULY 2009

NYC-WTC_000246819

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000246819Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000297646

Letter report detailing December 29, 2001 air sampling for metals and mercury at the referenced school.

Similar indexed content

Compare copies and versions →