NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Air sampling report, hydrocarbons and metals

Machine-extracted title · confidence 46%

Air sampling report for hydrocarbons, mercury, metals and silica at PS 234M.

NYC-WTC_000335198–000335201
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan December 3, 2002 Air Sampling for Hydrocarbons, Metals, Mercury & Silica Page 3 P. S 234(.Manhattan)ATC Protect No. 15-19125-0279

METAL SAMPLE RESULTS

Metal samples were analyzed for aluminum, cadmium, chromium, cobalt, copper, iron, magnesium, manganese, molybdenum, nickel and zinc. The limits of detection ranged from less than 0,0001 milligrams per sample (mg/sample) for cobalt to 0.002 mg/sample for iron. The airborne concentrations were calculated by dividing the amount found in the sample by the volume of air collected.

Chromium and nickel were detected in all samples however both metals were also detected in both blanks. When the average chromium and nickel levels in the blank are subtracted from the amounts in the samples, the airborne concentrations drop below the limits of detection except in one sample collected from the West Playground where a nickel concentration of 0.007 mg/m’ was found. Any chromium and nickel detected were already in the filter and did not come from the ambient air except that one sample for nickel collected from the West Playground. A trace amount of iron was found in the West Playground sample but it also found in one of the blanks. When the blank concentration is subtracted from the amount in the sample, the airborne concentration drops below the limit of detection. Aluminum was detected in one indoor sample, however it was found in one of the blank samples at an even higher concentration. The actual sample concentrai ion therefore was below the limit of detection.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 micrograms per cubic meter of air (ug/m^), this assumes a continuous exposure for one year. These samples were analyzed for total chromium (trivalent and hexavalent). All Cr concentrations were below the EPA screening level.

The EPA screening level for nickel is 2 ug/m^, the concentration detected in the West Playground sample was below this level.

The EPA has no standard or screening level for Al, Mg or Fe in ambient air.

MERCURY SAMPLE RESULTS

Mercury (Hg) was detected in these samples at levels that were indistinguishable from that detected in the blank.

The established regulatory value for mercury (OSHA: O.lmg/m’) is intended for industrial workplace exposures and is not generally applicable to office/school settings. There are no standards for mercury in indoor air in non-industrial situations. The EPA has no standard or guideline for mercury vapor in ambient air.

CITY_21MC100_003058550

NYC-WTC_000335200

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000335200Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air sampling report, PS 89M, Jan 2003

NYC-WTC_000196831

Letter from ATC Associates reporting air quality test results for hydrocarbons, mercury, metals, and silica at a school building.

Similar indexed content

Compare copies and versions →