NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan December 6, 2002
Air Sampling for Hydrocarbons, Metals, Mercury & Silica Page 3
P. S. SPfManhattan)■ ATC ProiectNo. 15-19125-0297
METAL SAMPLE Kl SI l tS
Metal samples were analyzed for aluminum, cadmium, chromium, cobalt, copper, iron,
magnesium, manganese, molybdenum, nickel and zinc. The limits of detection ranged
from less than 0.0001 milligrams per sample (mg/sample) for cobalt to 0.002 mg/sample
for iron. The airborne concentrations were calculated by dividing the amount found in
the sample by the volume of air collected.
Chromium and nickel were detected in all samples however both metals were also
detected in.both blanks. When, the average chromium level in the blanks is subtracted
from the amounts in the samples (that were higher than the blank average), the airborne
concentrations drop below the limits of detection. The airborne concentrations of nickel
found in the samples were much lower than the levels found in the average of the two
blanks. Any chromium and nickel detected were already in the filter and did not come
from the ambient air. Aluminum was detected in three samples with concentration ranged
from 0.001 mg/m^ to 0.005 mg/m\
The Environmental Protection Agency (EPA) has set a screening level for hexavalent
chromium (the more toxic form) m air of 0.6 micrograms per cubic meter of air (ug/m’),
this assumes a continuous exposure for one year. These samples were analyzed for total
chroniJLim (trivalent and hexavalent). All Cr concentrations detected in the samples
higher than the average of the two blanks were below the EPA- screening level.
The EPA screening level for nickel is 2 ug/in\ All Ni concentrations detected in the
samples were below the EPA screening level.
The EPA has no standard or screening level for Al in ambient air.
MERCURY SAMPLE RESULTS
Mercury (Hg) was detected in these samples at levels that were indistinguishable from
that detected in the blank.
The established regulatoriv value for mercury (OSHA; O.lmg/m^) is intended for
industrial workplace exposures and is not generally applicable to office/school settings.
There are no standards for mercury in indoor air in non-industrial situations. The EPA
has no standard or guideline for mercury vapor in ambient air.
SILICA SAMPLE RESULTS
Silica was not present above the limit of detection (<10 micrograms per sample) in any of
the samples.
The Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit
(PEL) is the only regulatory standard for silica exposure, however it is intended for
occupational exposure in settings such as foundries, sandblasting,- rock drilling, etc.
CITY_21MC100_003271309
NYC-WTC_000327872
OCR can misread numbers and units. Confirm readings against the page image before using them.