Mr. Bernard P. Orlan January 7, 2003 Air Sampling for Hydrocarbons, Metals, Mercury & Silica Page 3 P. S. 234(Manhattan)ATC ProiectNo. 15-19125-0279

METAL SAMPLE RESULTS

Metal samples were analyzed for aluminum, cadmium, chromium, cobalt, copper, iron, magnesium, manganese, molybdenum, nickel and zinc. The limits of detection ranged from less than 0.0001 milligrams per sample (mg/sample) for cobalt to 0.002 mg/sample for iron. The airborne concentrations were calculated by dividing the amount found in the sample by the volume of air collected.

Chromium was detected in all samples however it was also detected in both the blanks. Zinc was detected in three samples and also in one of the blanks. When the average chromium levels in the blank are subtracted from the amounts in the samples, the airborne concentrations drop below the limits of detection. When the zinc detected in one of the blanks is subtracted from the amounts in the samples, the airborne concentrations drop below the limits of detection. Any chromium and zinc detected were already in the filter and did not come from the ambient air.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 micrograms per cubic meter of air (ug/m^), this assumes a continuous exposure for one year. These samples were analyzed for total chromium (trivalent and hexavalent). All Cr concentrations were below the EPA screening level.

The EPA has no standard or screening level for zinc in ambient air.

MERCURY SAMPLE RESULTS

Mercury (Hg) was detected in these samples at levels that were indistinguishable from that detected in the blank.

The established regulatory value for mercury (OSHA; O.lmg/m^) is intended for industrial workplace exposures and is not generally applicable to office/school settings. There are no standards for mercury in indoor air in non-industrial situations. The EPA does not have a standard or guideline for mercury vapor in ambient air.

SILICA SAMPLE RESULTS

Silica was not present above the limit of detection (<10 micrograms per sample) in any of the samples.

The Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL) is the only regulatory standard for silica exposure, however it is intended for occupational exposure in settings such as foundries, sandblasting, rock drilling, etc. The EPA does not have an ambient-air quality standard or guideline for silica.

CITY_21MC100_0 03058290

NYC-WTC_000335015

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000335015Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →