Table RI; Areas within buildings which had either asbestos in the dust by PLM or TEM analysis, or
MMVF in the settled dust by PLM analysis. The range of asbestos and MMVF values for each type of
location are included.
Number of Range of Number of Range of
Total locations with Asbestos locations MMVF
Areas Asbestos in found with MMVF found
sampled settled dust (% by PLM or in settled (% by PLM)
(PLM or TEM) TEM)b dust (PLM) b
Asbestos (PLM) = 14
Outdoor Asbestos (TEM) =12 7 <l%-3.4% 9 15-72%
MMVF (PLM) =13 (50%) a (69%)
Asbestos (PLM) = 26
Common Asbestos (TEM) = 25 5 <1%- 1.5% 11 5 - 27%
MMVF (PLM) = 26 (20%) (42%)
Asbestos (PLM) = 57
Residential Asbestos (TEM) =52 10 <1%- 1.5% 23 2-35% c
MMVF (PLM) = 57 (18) (40%)
Asbestos (PLM) = 29
Whole Asbestos (TEM) = 29 12 <l%-3.4% 17 2 - 72%
Building MMVF (PLM) = 29 (41%) (59%)
Comparison
Buildings
Asbestos (PLM) = 3
Common Asbestos (TEM) = 3 0 None Detected 0 None
MMVF (PLM) = 3 (0%) by PLM or (0%) Detected by
TEM PLM
Asbestos (PLM) = 5
Residential Asbestos (TEM) =4 0 None Detected 0 None
MMVF (PLM) = 5 (0%) by PLM or (0%) Detected by
TEM PLM
Notes:
a.The number of locations containing asbestos in dust reflects locations with asbestos detected by
either PLM or TEM (<1% or greater). The percentage of locations with asbestos detected is based
on the number of PLM samples.
b. The figures here are visual estimates of the percent of material seen by PLM analysis to be
MMVF. This is not a weight or volume percent of the material.
c. One residential unit had an extra settled dust sample taken from a window silt which contained
40% MMVF by PLM.
CONFIDENTIAL, CITY_21MC100_003434278
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000242888
OCR can misread numbers and units. Confirm readings against the page image before using them.