Draft; Do not Cite, Quote, or Release May 30, 2002 Last saved by CVLee

2170 Table RI: Areas within buildings which had either asbestos in the dust by PLM or TEM analysis, or MMVF in the settled dust by PLM analysis. The range of asbestos and MMVF values for each type of location are included. Number of Range of Number of Range of Total locations with Asbestos locations MMVF Areas Asbestos in found with MMVF found sampled settled dust (% by PLM or in settled (% by PLM) *’ (PLM orTEMF TEM)” dust (PLM)' Asbestos (PLM) = 14 Outdoor Asbestos (TEM) =12 6 <1% - 3.4 % 9 15-72% MMVF (PLM) =13 (43%) (69%)

Asbestos (PLM) =26 Common Asbestos (TEM) =25 5 <1% - 1.5% 11 5-27% MMVF (PLM) =26 (20%) (42%) Asbestos (PLM) =57 Residential Asbestos (TEM) =52 10 <1%- 1.5% 23 2-35% MMVF (PLM) =57 (18%) (40%)

Asbestos (PLM) = 29 Whole Asbestos (TEM) = 29 12 <1% - 3.4% 17 2 - 72% Building MMVF (PLM) =29 (41%) (59%)

Compariso n Buildings Asbestos (PLM) =3 Common Asbestos (TEM) = 3 0 None Detected 0 None MMVF (PLM) = 3 (0%) by PLM or (0%) Detected by TEM PLM Asbestos (PLM) = 5 Residential Asbestos (TEM) =4 0 None Detected 0 None MMVF (PLM) = 5 (0%) by PLM or (0%) Detected by TEM PLM Notes: a. The number of locations containing asbestos in dust reflects locations with asbestos detected by either PLM or TEM (<1% or greater). The percentage of locations with asbestos detected is calculated from the number of PLM samples. b. The values are visual estimates of the percent of material seen by PLM analysis to be either asbestos or MMVF. This is not a weight or volume percent of the material. c. The percentage of locations with MMVF detected is calculated from the number of MMVF PLM samples. d. One residential unit had an extra settled dust sample taken from a window sill which contained 40% MMVF by PLM. 2171 2172 2173 2174 2175

CITY_21MC100_012171144

NYC-WTC_000320320

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320320Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275863

Investigation report on exposures to airborne and dust in Lower Manhattan.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →