NYC 9/11 Public Portal Document
r'~\
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/19/01
asbestos fiber analysis by transmission electron microscopy (TEM)
i_J With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
: ; Sample Identification Analysis Parameters
Project/Sice: 40 Rector Street, NY, NY TEM Sample No.: 5729 - 61854
Floors 16~18
Date Received; 10/19/01 Grid Openings Analyzed:__ 6
‘ Project Sample No. Average Grid Opening; 1Q6.Q0 urn
L.,J
Air Volume: 1300 liters Total Area Analyzed; 0.0674 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity; 14.8 s/mm2
Effective Area:385mm2 0.0044 s/cc
Lj fibrous particulates analyzed
Number Observed CONCENTRATION
>............ '■)
Total
Single Matrix Total. struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5um Struct/mm2 st- ngm/m3
Hl
'Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
<.J Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
\ Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
(J Amphibole Asbestos Type: None detected
R The Analysis was carried out in accordance with the approved TEM method.
VtJ
This laboratory is in compliance with the quality specified for the method.
R
Analyzed by: Report Reviewed by:
n Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237385
OCR can misread numbers and units. Confirm readings against the page image before using them.