NYC 9/11 Public Portal Document
1
U
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/19/01
' ’ ASBESTOS FIBER ANALYSIS BY TRTXNSMISSION ELECTRON MICROSCOPY (TEM)
with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Pinal Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, NY, NY TEM Sample No.; 5729 - 61857
' Floors 16-18
Date Received: 10/19/01 Grid Openings Analyzed:__ 6
' ' Project Sample No.: 12 Average Grid Opening: 106.00 urn
Air Volume: 1300 liters Total Area Analyzed: 0.0674 mm2
I
Filter Type; MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 14.8 3/mm2
Effective Area: 385 nmi2 0.0044 s/cc
U FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5um Struct/mni2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
vi Non-asbestos fiber i.d. (EDS/SAED): None detected
) Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
!J Analyzed by: Report Reviewed by;
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237388
OCR can misread numbers and units. Confirm readings against the page image before using them.