NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
n 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/20/01
n ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, SPA Federal Register (4C CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No.: 5537 - 59311
Lobby & 16th Floor
Date Received; 09/20/01 Grid Openings Analyzed:__ 4
Project Sample No.; 07 Average Grid Openinp: 106.00 um
Air Volume: 1800 liters Total Area Analyzed; 0.0450 mm2
Filter T’/pe: MCE 25 mm diam. Pore Size ; 0.45 um Analytical Sensitivity:22:2 s/2!S!2
Effective Area: 385 mm2 0.0048 s/cc
FIBROUS PARTICULATES ANALYZED
Mumber Observed CONCENTRATION
; 1
Total
Single Matrix Total. Struct. Filter Air
L_; Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ngm/m3
rd Chrysotile Asbestos 0 0 0 0 0 0 0.0 o.cooo 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
.d
Ambiguous 0 0 0 0 0 0 C.o 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 C.0 0.0000 0
i.. ■)
Non-Asbestos 0 0 0 0 0 0 0. c 0.0000 N/a
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method.
/ 1 This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
n
NYC-WTC_000237364
OCR can misread numbers and units. Confirm readings against the page image before using them.