NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
I.: )
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 R'eport Date: 09/25/01
, ASBESTOS FIBER TdSTALYSIS BY TRZkNSMISSION ELECTRON MICROSCOPY (TEM)
! With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
"J Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763;, Vol. 52, No. 210, October 30, 1987
;.h
Sample Identification Analysis Parameters
Project/Site: 4 0 Rector Street, 4 0 Rector St., NY, NY TEM Sample No.' : 5554 - S9460
Floors 19, 18, 10, 9, £
Dats Received: 09/24/01 Grid Openings Analyzed:__ 5
Project Sample No. :_092Zi_ii2 Average Grid Opening: 106;00 urn
Air Volume: 1350 liters Total Area Analyzed: 0.0562 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 17.8 s/mm2
Effective Area: 385 mm2 . 0■0051 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. .Struct. Filter Air
Fibers Bundles Clusters Struct. Struct ■=5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 1 0 0 1 1 17.8 0.0051 167
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Tunbiguous 0 0 0 0 0 0 0.0 0.0000 0
- Total asbestos (includes ambiguous structures) 1 1 17.8 0.0051 167
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 ■ N/A
Totals (All Structures) 1 1 17.8 0.0051 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
CT Analyzed by: Report Reviewed by;
LJ
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
L-J
NYC-WTC_000237334