NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 09/25/01
, T ASBESTOS FIBER TiNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
' Sample Identification Analysis Parameters
Project/Site: ^O Rector Street, 40 Rector St., NY, NY TSM Sample No.: 5554 59455
Floors 15, 18, 10,9, 8
Date Received: 09/24/01 Grid Openings Analyzed:_ 6
Project Sample No. : 09-24-14 Average Grid Opening; 106.00 um
Air Volume: 1330 liters Total Area Analyzed: 0.0674 mm2
: Filter Type: MCE 25 mm diam. Pore Size; Q.45 um Analytical Sensitivity.- 14.8 s/mmO
I Effective Area: 385 mm2 0.0043 s/cc
FIBROUS PARTICULATES. ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ngm/m3
0 Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos {includes ambiguous structures) 0 -0 0.0 0.0000 0
Kon-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0. 0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
pl Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237331